Clearance of solvents and small molecule impurities in antibody drug conjugates via ultrafiltration and diafiltration operation

Biotechnol Prog. 2020 Jan;36(1):e2923. doi: 10.1002/btpr.2923. Epub 2019 Oct 16.

Abstract

Ultrafiltration and diafiltration (UF/DF) processes by tangential flow filtration (TFF) are frequently used for removal of solvents and small molecule impurities and for buffer exchange for biopharmaceutical products. Antibody-drug conjugates (ADCs) as an important class of biological therapeutics, carry unique solvents and small molecule impurities into the final UF/DF step as compared to standard antibody preparation. The production process of ADCs involves multiple chemical steps, for example, reduction and conjugation. The clearance of these solvents and small molecules by UF/DF, specifically the DF step, has been assessed and described herein. The rates of clearance for all the impurities in this study are close to the ideal clearance with no apparent interaction with either the protein or the TFF membrane and system. The effect of process variables during DF, such as pH, temperature, membrane loading, transmembrane pressure, and cross flow rate, has also been evaluated and found to have minimal impact on the clearance rate. These results demonstrate efficient clearance of solvents and small molecule impurities related to the ADC process by the DF process and provide a general data package to facilitate risk assessments based on the sieving factors and program specific needs.

Keywords: ADC; UF/DF; impurity clearance.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chromatography, High Pressure Liquid
  • Filtration*
  • Hydrogen-Ion Concentration
  • Immunoconjugates / chemistry*
  • Pressure
  • Small Molecule Libraries / chemistry
  • Small Molecule Libraries / isolation & purification*
  • Solvents / chemistry
  • Solvents / isolation & purification
  • Temperature

Substances

  • Immunoconjugates
  • Small Molecule Libraries
  • Solvents