Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique

Int J Cardiovasc Imaging. 2020 Jan;36(1):111-119. doi: 10.1007/s10554-019-01697-4. Epub 2019 Sep 14.

Abstract

Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 ± 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman's correlation coefficient (ρ) and Bland-Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); ρ: 0.85, p < 0.01; bias (limit of agreement): - 0.01 g (- 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.

Keywords: Acute myocardial infarction; Biomarker; Intramyocardial hemorrhage; Magnetic resonance imaging; Quantification; Semi-automated threshold method.

MeSH terms

  • Aged
  • Automation
  • Biomarkers / blood
  • Creatine Kinase, MB Form / blood
  • Female
  • Hemorrhage / diagnostic imaging*
  • Hemorrhage / pathology
  • Humans
  • Imaging, Three-Dimensional / methods*
  • Magnetic Resonance Imaging, Cine / methods*
  • Male
  • Middle Aged
  • Myocardial Reperfusion / adverse effects*
  • Myocardial Reperfusion Injury / blood
  • Myocardial Reperfusion Injury / diagnostic imaging*
  • Myocardial Reperfusion Injury / etiology
  • Myocardial Reperfusion Injury / pathology
  • Myocardium / enzymology
  • Myocardium / pathology*
  • Predictive Value of Tests
  • Prognosis
  • Reproducibility of Results
  • Retrospective Studies

Substances

  • Biomarkers
  • Creatine Kinase, MB Form