Validation and standardization of the ETP-based activated protein C resistance test for the clinical investigation of steroid contraceptives in women: an unmet clinical and regulatory need

Clin Chem Lab Med. 2020 Jan 28;58(2):294-305. doi: 10.1515/cclm-2019-0471.

Abstract

Background Regulatory bodies recommend the use of an assay based on the assessment of the endogenous thrombin potential (ETP) for the investigation of the activated protein C resistance (APCr) in the development of steroid contraceptives in women. However, the assays described in the literature are home-made and not standardized regarding the method, the reagents, the reference plasma and the quality controls. In the absence of any commercially available method, we aimed at validating the ETP-based APCr assay. Methods The validation was performed according to regulatory standards. The method targets a 90% inhibition of the ETP in healthy donors in the presence of APC compared to the same condition in the absence of APC. As a large-scale production of a pool of plasma from well-selected healthy donors is impossible, algorithms were applied to a commercial reference plasma to correlate with the selected pool. Results Repeatability and intermediate precision passed the acceptance criteria. The assay demonstrated a curvilinear dose response to protein S and APC concentrations (R2 > 0.99). Analysis of plasma samples from 47 healthy individuals (22 women not taking combined hormonal contraceptives [CHC], and 25 men not Factor V Leiden carriers) confirmed the validity of the test, with a mean inhibition percentage of 90%. Investigations in 15 women taking different contraceptives and in two subjects with Factor V Leiden confirmed the good sensitivity and performance of the assay. Conclusions This validation provides the pharmaceutical industry, the regulatory bodies and physicians with a reproducible, sensitive and validated gold-standard ETP-based APCr assay.

Keywords: Factor V Leiden; activated protein C resistance; blood coagulation test; combined hormonal contraceptive; endogenous thrombin potential; protein S deficiency.

MeSH terms

  • Activated Protein C Resistance / diagnosis*
  • Adult
  • Algorithms
  • Blood Coagulation Tests / methods
  • Blood Coagulation Tests / standards*
  • Contraceptive Agents / administration & dosage
  • Factor V / analysis
  • Female
  • Humans
  • Male
  • Protein C / analysis
  • Protein C / standards*
  • Reference Standards
  • Reproducibility of Results

Substances

  • Contraceptive Agents
  • Protein C
  • factor V Leiden
  • Factor V