Are wearable heart rate measurements accurate to estimate aerobic energy cost during low-intensity resistance exercise?

PLoS One. 2019 Aug 22;14(8):e0221284. doi: 10.1371/journal.pone.0221284. eCollection 2019.

Abstract

The aim of the present study was to assess the accuracy of heart rate to estimate energy cost during eight resistance exercises performed at low intensities: half squat, 45° inclined leg press, leg extension, horizontal bench press, 45° inclined bench press, lat pull down, triceps extension and biceps curl. 56 males (27.5 ± 4.9 years, 1.78 ± 0.06 m height, 78.67 ± 10.7 kg body mass and 11.4 ± 4.1% estimated body fat) were randomly divided into four groups of 14 subjects each. Two exercises were randomly assigned to each group and subjects performed four bouts of 4-min constant-intensity at each assigned exercise: 12%, 16%, 20% and 24% 1-RM. Exercise and intensity order were random. Each subject performed no more than 2 bouts in the same testing session. A minimum recovery of 24h was kept between sessions. During testing VO2 was measured with Cosmed K4b2 and heart rate was measured with Polar V800 monitor. Energy cost was calculated from mean VO2 during the last 30-s of each bout by using the energy equivalent 1 ml O2 = 5 calorie. Linear regressions with heart rate as predictor and energy cost as dependent variable were build using mean data from all subjects. Robustness of the regression lines was given by the scatter around the regression line (Sy.x) and Bland-Altman plots confirmed the agreement between measured and estimated energy costs. Significance level was set at p≤0.05. The regressions between heart rate and energy cost in the eight exercises were significant (p<0.01) and robustness was: half squat (Sy.x = 0,48 kcal·min-1), 45° inclined leg press (Sy.x = 0,54 kcal·min-1), leg extension (Sy.x = 0,59 kcal·min-1), horizontal bench press (Sy.x = 0,47 kcal·min-1), 45° inclined bench press (Sy.x = 0,54 kcal·min-1), lat pull down (Sy.x = 0,28 kcal·min-1), triceps extension (Sy.x = 0,08 kcal·min-1) and biceps curl (Sy.x = 0,13 kcal·min-1). We conclude that during low-intensity resistance exercises it is possible to estimate aerobic energy cost by wearable heart rate monitors with errors below 10% in healthy young trained males.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Energy Metabolism / physiology*
  • Heart Rate / physiology*
  • Humans
  • Linear Models
  • Male
  • Monitoring, Physiologic / instrumentation*
  • Muscle, Skeletal / physiology*
  • Oxygen Consumption / physiology*
  • Resistance Training / methods*
  • Wearable Electronic Devices

Grants and funding

This research was supported by Norte Portugal Regional Operational Programme (NORTE 2020), through Portugal 2020 and the European Regional Development Fund, NanoSTIMA, NORTE-01-0145- FEDER-000016 to VMR. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.