Simplified Direct PCR Method for Reference Buccal Samples Using a Non-FTA Card by Omitting the Pretreatment Step

J Forensic Sci. 2020 Jan;65(1):209-213. doi: 10.1111/1556-4029.14147. Epub 2019 Aug 21.

Abstract

When using non-FTA cards in commercial multiplex STR kits for direct PCR, pretreatment steps with specific buffers are recommended. Here, we designed a rapid direct PCR method utilizing a non-FTA card, Oral Cell Sampling Kit, by omitting the pretreatment step involving Prep-n-Go™ Buffer, and it showed compatibility with the GlobalFiler™ Express PCR Amplification Kit, GlobalFiler™ PCR Amplification Kit, and PowerPlex® Fusion system. To optimize the PCR conditions, we tested the method with different final PCR volumes and cycles. Finally, we conducted a performance test using 50 Korean buccal samples and confirmed the high performance of the method, detecting more than 90% of the samples with full profiles when using GlobalFiler™ PCR Amplification Kit and PowerPlex® Fusion system at 29 cycles in a 10 μL final PCR volume. Thus, we report a simple direct PCR set-up to analyze reference samples collected using a non-FTA card manufactured in Korea.

Keywords: DNA typing; Oral Cell Sampling Kit; Prep-n-Go™ Buffer; direct polymerase chain reaction; forensic science; reference samples.

MeSH terms

  • DNA Fingerprinting / methods
  • Female
  • Humans
  • Microsatellite Repeats
  • Mouth Mucosa / chemistry
  • Polymerase Chain Reaction / methods*
  • Republic of Korea
  • Specimen Handling / instrumentation*
  • Specimen Handling / methods