Progression of ascending aortopathy may not occur after transcatheter aortic valve replacement in severe bicuspid aortic stenosis

Korean J Intern Med. 2021 Mar;36(2):332-341. doi: 10.3904/kjim.2019.089. Epub 2019 Aug 14.

Abstract

Background/aims: We evaluated changes in the ascending aorta dimension post-transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BiAV) and tricuspid aortic valve (TAV) patients.

Methods: Patients with severe aortic stenosis undergoing TAVR at Seoul National University Hospital were consecutively recruited. Patients with less than 12 months' follow-up and/or with an ascending aorta size larger than 50 mm were excluded. The ascending aorta size was measured on a parasternal long axis view using transthoracic echocardiography.

Results: Among the 67 patients who were included (age: 76.5 ± 6.5 years; male: 52.2%; AV area: 0.67 ± 0.15 cm2), 19 (28.4%) had BiAV; 48 (71.6%) had TAV. The median (interquartile ranges) follow-up duration was 398 days (361 to 451). BiAV patients were younger (73.2 ± 7.2 vs. 77.8 ± 5.8, p = 0.008), and had lower incidences of chronic renal disease (5.3% vs. 35.4%, p = 0.014) and history of coronary intervention (15.8% vs. 50.0%, p = 0.013), than TAV patients. On pre-procedural echocardiography, the ascending aorta dimensions in BiAV patients were larger than those in TAV patients (40.5 ± 3.8 mm vs. 35.9 ± 4.2 mm, p < 0.005). The ascending aorta dimension changed minimally during follow-up; post-TAVR, the ascending aorta's growth rate was -0.11 ± 1.9 and 0.26 ± 1.8 mm/yr in patients with BiAV and TAV, respectively (p = 0.50). Progression of the ascending aorta's dimension postTAVR was not clinically significant in BiAV patients.

Conclusion: The concern about the progression of aortopathy in BiAV patients post-TAVR may not be a clinical issue. This should be confirmed in studies with a larger population and with a longer follow-up duration.

Keywords: Aortic aneurysm; Aortic valve stenosis; Bicuspid; Transcatheter aortic valve replacement.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / etiology
  • Aortic Valve Stenosis* / surgery
  • Heart Valve Diseases* / surgery
  • Humans
  • Male
  • Retrospective Studies
  • Seoul
  • Transcatheter Aortic Valve Replacement* / adverse effects