Perianchor Cyst Formation After Arthroscopic Rotator Cuff Repair Using All-Suture-Type, Bioabsorbable-Type, and PEEK-Type Anchors

Arthroscopy. 2019 Aug;35(8):2284-2292. doi: 10.1016/j.arthro.2019.03.032. Epub 2019 Jul 23.

Abstract

Purpose: This study aimed to identify the difference in postoperative perianchor bone reactions in different groups of patients who underwent rotator cuff tear repairs with all-suture-, bioabsorbable screw-, and PEEK (polyether ether ketone)-type suture anchors. Furthermore, the rate of rotator cuff retear and its association with perianchor bone reactions based on the different anchors used were investigated. Moreover, their impact on the clinical outcome of patients was examined.

Methods: The study included 213 patients who underwent arthroscopic single-row repair and were divided into 3 groups according to the suture anchor used: all-suture (n = 137), biodegradable (n = 36), and PEEK (n = 40) anchor groups. The clinical outcomes and magnetic resonance imaging findings were evaluated at a mean follow-up of 9.6 months. The perianchor bone reaction at the anchor site was categorized according to grades. Patients were classified based on repair integrity into the healed and retear groups with Sugaya type I to III and Sugaya type IV to V, respectively.

Results: No statistically significant differences in Constant scores and retear rates were observed between the groups (P = .934 and P = .548, respectively). Magnetic resonance imaging showed that the total number of perianchor cysts formed postoperatively was 23 (10.8% [23 of 213 patients]). Moreover, the proportions of perianchor cysts were 8.8%, 16.7%, and 12.5% in the all-suture-type, bioabsorbable-, and PEEK-type anchor groups, respectively (P = .485). In the retear group, the incidence rate was significantly increased with higher grades of perianchor bone reaction (P = .001). The tear size and perianchor bone reaction were found to be independent factors that affected the incidence of retear.

Conclusions: Perianchor cyst formation was observed in 10.8% of cases after the use of suture anchors for arthroscopic rotator cuff repair. No significant differences were observed among all-suture-type, bioabsorbable-type, and PEEK-type anchors in terms of visual analog scale and Constant scores, retear rates, and perianchor bone reactions. However, the retear rate was associated with a greater perianchor cystic reaction and larger tear size.

Level of evidence: Level III, retrospective comparative trial.

MeSH terms

  • Absorbable Implants*
  • Aged
  • Arthroplasty / adverse effects
  • Arthroscopy / instrumentation*
  • Arthroscopy / methods
  • Benzophenones
  • Cysts / surgery
  • Female
  • Follow-Up Studies
  • Humans
  • Ketones / chemistry*
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Polyethylene Glycols / chemistry*
  • Polymers
  • Postoperative Period
  • Range of Motion, Articular
  • Retrospective Studies
  • Rotator Cuff / surgery*
  • Rotator Cuff Injuries / surgery*
  • Suture Anchors*
  • Sutures / adverse effects

Substances

  • Benzophenones
  • Ketones
  • Polymers
  • polyetheretherketone