Highly sensitive and selective electrochemical paper-based device using a graphite screen-printed electrode modified with molecularly imprinted polymers coated Fe3O4@Au@SiO2 for serotonin determination

Anal Chim Acta. 2019 Oct 24:1077:255-265. doi: 10.1016/j.aca.2019.05.047. Epub 2019 May 31.

Abstract

Herein, we propose a highly sensitive and selective three-dimensional electrochemical paper-based analytical device (3D-ePAD) to determine serotonin (Ser). It uses a graphite-paste electrode modified with nanoparticles coated with molecularly imprinted polymer (MIP). Fe3O4@Au nanoparticles were encapsulated with silica to create novel nano-sized MIP. Morphology and structural characterization reveal that silica imprinted sites (Fe3O4@Au@SiO2) synthesized via sol-gel methods provide excellent features for Ser detection, including high porosity, and greatly improve analyte diffusion and adsorption to provide a faster response by the MIP sensor. The template molecule was effectively removed by solvent extraction to provide a greater number of specific cavities that enhance analyte capacity and sensitivity. The 3D-ePAD was fabricated by alkyl ketene dimer (AKD)-inkjet printing of a circular hydrophobic detection zone on filter paper for application of aqueous samples, coupled with screen-printed electrodes on the paper, which was folded underneath the hydrophobic zone. The sensor was constructed by drop coating of Fe3O4@Au@SiO2-MIP nanocomposites on the graphite electrode (GPE) surface. The MIP sensor (Fe3O4@Au@SiO2-MIP/GPE) was used in the detection of Ser by linear-sweep voltammetry (LSV) in 0.1 M phosphate buffer at pH 8.0. The device exhibits high sensitivity toward Ser, which we attribute to synergistic effects between catalytic properties, electrical conductivity of Fe3O4@Au@SiO2, and significantly increased numbers of imprinted sites. Ser oxidation was observed at +0.39 V. Anodic peak currents for Ser show linearity from 0.01 to 1000 μM (y = 0.0075 ± 0.0049 x + 0.4071 ± 0.0052, r2 = 0.993), with a detection limit of 0.002 μM (3S/N). The device provides good repeatability (%relative standard deviations; RSD) = 4.23%, calculated from the current responses of ten different MIP sensors). The device also exhibits high selectivity and reproducibility (%RSD = 8.35%, obtained from five calibration plots). The analytical performance of the device is suitable for the determination of Ser in pharmaceutical capsules and urine samples.

Keywords: Gold-coated magnetite (Fe(3)O(4)@Au); Graphite screen-printed electrode; Molecularly imprinted polymer (MIP); Serotonin; Three-dimensional electrochemical paper-based analytical device (3D-ePAD).

MeSH terms

  • Electrochemical Techniques / instrumentation
  • Electrochemical Techniques / methods
  • Electrodes
  • Gold / chemistry*
  • Graphite / chemistry
  • Limit of Detection
  • Magnetite Nanoparticles / chemistry*
  • Molecular Imprinting
  • Paper
  • Povidone / chemistry*
  • Serotonin / analysis*
  • Silicon Dioxide / chemistry*

Substances

  • Magnetite Nanoparticles
  • Serotonin
  • Gold
  • Silicon Dioxide
  • Graphite
  • Povidone