Serum pepsinogen assay is not recommended for the diagnosis of esophageal squamous cell carcinoma: a systematic review and meta-analysis

Cancer Manag Res. 2019 Jun 27:11:5643-5654. doi: 10.2147/CMAR.S196760. eCollection 2019.

Abstract

Background: Serum pepsinogen I (PGI) concentration and PGI/PGII ratio (PGR) are often used as serological markers for gastric fundus atrophy (AGA) and gastric carcinoma. However, their diagnostic value in esophageal carcinoma (EC) is inaccurate. Methods: This study evaluated the diagnostic value of PGI and PGR in EC by searching the PubMed, Web of Science, Embase, Cochrane Library and Cochrane Central Register of Controlled Trials databases for literature on the diagnosis of EC with PGI and PGR from January 1, 2000 to October 2, 2018. The included literature were systematically evaluated using QUSDAS-2 software. Meta-analysis was conducted using STATA 15.0 software. The summary receiver operating characteristic curve (SROC) accuracy was plotted, the area under the curve was calculated. Results: A total of 84 papers were selected, and after screening, nine papers on esophageal squamous cell carcinoma (ESCC) were finally included. Results showed low an ESCC-specific diagnostic sensitivity (0.27), high specificity (0.85), and 0.63 AUC of SROC when PGI≤70 ng/mL. When PGR≤3, the ESCC-specific diagnostic sensitivity was low (0.29), the specificity was high (0.83), and the AUC of SROC was 0.63. Conclusion: According to the current research results, PGI≤70 ng/mL or PGR≤3 diagnostic ESCC sensitivity is low, and specificity is high. These findings indicate that neither PGI≤70 ng/mL nor PGR≤3 can be used as an ESCC-screening index.

Keywords: PGI; PGR; diagnosis; esophageal squamous cell carcinoma; meta-analysis.