High Precision Compensation for a Total Reflection Prism Laser Gyro Bias in Consideration of High Frequency Oscillator Voltage

Sensors (Basel). 2019 Jul 6;19(13):2986. doi: 10.3390/s19132986.

Abstract

Traditional compensation methods based on temperature-related parameters are not effective for complex total reflection prism laser gyro (TRPLG) bias variation. Because the high frequency oscillator voltage (UHFO) fundamentally affects the TRPLG bias, and the UHFO has a stronger correlation with the TRPLG bias when compared with the temperature, an introduction of UHFO into the TRPLG bias compensation can be evaluated. In consideration of the limitations of least squares (LS) regression and multivariate stepwise regression, we proposed a compensation method for TRPLG bias based on iterative re-weighted least squares support vector machine (IR-LSSVM) and compared with LS regression, stepwise regression, and LSSVM algorithm in large temperature cycling experiments. When temperature, slope of temperature variation, and UHFO were selected as inputs, the IR-LSSVM based on myriad weight function improved the TRPLG bias stability by 61.19% to reach the maximum and eliminated TRPLG bias drift. In addition, the UHFO proved to be the most important parameter in the process of TRPLG bias compensation; accordingly, it can alleviate the shortcomings of traditional compensation based on temperature-related parameters and can greatly improve the TRPLG bias stability.

Keywords: TRPLG bias stability; complex TRPLG bias variation; high frequency oscillator voltage (UHFO); iterative re-weighted least squares support vector machine (IR-LSSVM); total reflection prism laser gyro (TRPLG).