High-Resolution PET Cisternography With 64Cu-DOTA for CSF Leak Detection

Clin Nucl Med. 2019 Sep;44(9):735-737. doi: 10.1097/RLU.0000000000002695.

Abstract

Intracranial hypotension may lead to chronic, debilitating symptoms, and severe complications. The underlying CSF leak may be difficult to localize. To establish a new diagnostic option for the detection of CSF leaks, Cu-DOTA was developed as a tracer for PET imaging. PET/CT imaging was possible with high resolution and without complications. In one patient, the exact site of a dural tear was identified, enabling successful surgical treatment. PET cisternography with Cu-DOTA appears to be safe and able to locate a CSF leak. It has the potential to be a problem-solving modality in cases with inconclusive CT, MR, and/or scintigraphic findings.

Publication types

  • Case Reports

MeSH terms

  • Cerebrospinal Fluid Leak / diagnostic imaging*
  • Copper Radioisotopes*
  • Heterocyclic Compounds, 1-Ring*
  • Humans
  • Male
  • Middle Aged
  • Positron Emission Tomography Computed Tomography*
  • Safety
  • Signal-To-Noise Ratio*

Substances

  • Copper Radioisotopes
  • Copper-64
  • Heterocyclic Compounds, 1-Ring
  • 1,4,7,10-tetraazacyclododecane- 1,4,7,10-tetraacetic acid