Non-Cartesian GRAPPA and coil combination using interleaved calibration data - application to concentric-ring MRSI of the human brain at 7T

Magn Reson Med. 2019 Nov;82(5):1587-1603. doi: 10.1002/mrm.27822. Epub 2019 Jun 10.

Abstract

Purpose: Proton MR spectroscopic imaging (MRSI) benefits from B0 ≥ 7T and multichannel receive coils, promising substantial resolution improvements. However, MRSI acquisition with high spatial resolution requires efficient acceleration and coil combination. To speed up the already-fast sampling via concentric rings, we implemented additional, non-Cartesian, hybrid through-time/through-k-space (tt/tk)-generalized autocalibrating partially parallel acquisition (GRAPPA). A new multipurpose interleaved calibration scan (interleaved MUSICAL) acquires reference data for both coil combination and PI. This renders the reconstruction process (especially PI) less sensitive to instabilities.

Methods: Six healthy volunteers were scanned at 7T. Three calibration datasets for coil combination and PI were recorded: a) iMUSICAL, b) static MUSICAL as prescan, c) moved MUSICAL as prescan with misaligned head position. The coil combination performance, including motion sensitivity, of iMUSICAL was compared to MUSICAL for single-slice free induction decay (FID)-MRSI. Through-time/through-k-space-GRAPPA with constant/variable-density undersampling was evaluated on the same data, comparing the three calibration datasets. Additionally, the proposed method was successfully applied to 3D whole-brain FID-MRSI.

Results: Using iMUSICAL for coil combination yielded the highest signal-to-noise ratio (SNR) (+9%) and lowest Cramer-Rao lower bounds (CRLBs) (-6%) compared to both MUSICAL approaches, with similar metabolic map quality. Also, excellent mean g-factors of 1.07 and low residual lipid aliasing were obtained when using iMUSICAL as calibration data for two-fold, variable-density undersampling, while significantly degraded metabolic maps were obtained using the misaligned MUSICAL calibration data.

Conclusion: Through-time/through-k-space-GRAPPA can accelerate already time-efficient non-Cartesian spatial-spectral 2D/3D-MRSI encoding even further. Particularly promising results have been achieved using iMUSICAL as a robust, interleaved multipurpose calibration for MRSI reconstruction, without extra calibration prescan.

Keywords: 7 tesla; MR spectroscopic imaging; hybrid through-time/through-k-space GRAPPA; multichannel coil combination; non-Cartesian concentric ring; parallel imaging.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Brain / metabolism*
  • Brain Mapping / methods*
  • Calibration
  • Healthy Volunteers
  • Humans
  • Image Enhancement / methods*
  • Image Processing, Computer-Assisted / methods
  • Imaging, Three-Dimensional*
  • Magnetic Resonance Spectroscopy / instrumentation
  • Magnetic Resonance Spectroscopy / methods*
  • Signal-To-Noise Ratio