Scoring reading parameters: An inter-rater reliability study using the MNREAD chart

PLoS One. 2019 Jun 7;14(6):e0216775. doi: 10.1371/journal.pone.0216775. eCollection 2019.

Abstract

Purpose: First, to evaluate inter-rater reliability when human raters estimate the reading performance of visually impaired individuals using the MNREAD acuity chart. Second, to evaluate the agreement between computer-based scoring algorithms and compare them with human rating.

Methods: Reading performance was measured for 101 individuals with low vision, using the Portuguese version of the MNREAD test. Seven raters estimated the maximum reading speed (MRS) and critical print size (CPS) of each individual MNREAD curve. MRS and CPS were also calculated automatically for each curve using two different algorithms: the original standard deviation method (SDev) and a non-linear mixed effects (NLME) modeling. Intra-class correlation coefficients (ICC) were used to estimate absolute agreement between raters and/or algorithms.

Results: Absolute agreement between raters was 'excellent' for MRS (ICC = 0.97; 95%CI [0.96, 0.98]) and 'moderate' to 'good' for CPS (ICC = 0.77; 95%CI [0.69, 0.83]). For CPS, inter-rater reliability was poorer among less experienced raters (ICC = 0.70; 95%CI [0.57, 0.80]) when compared to experienced ones (ICC = 0.82; 95%CI [0.76, 0.88]). Absolute agreement between the two algorithms was 'excellent' for MRS (ICC = 0.96; 95%CI [0.91, 0.98]). For CPS, the best possible agreement was found for CPS defined as the print size sustaining 80% of MRS (ICC = 0.77; 95%CI [0.68, 0.84]). Absolute agreement between raters and automated methods was 'excellent' for MRS (ICC = 0.96; 95% CI [0.88, 0.98] for SDev; ICC = 0.97; 95% CI [0.95, 0.98] for NLME). For CPS, absolute agreement between raters and SDev ranged from 'poor' to 'good' (ICC = 0.66; 95% CI [0.3, 0.80]), while agreement between raters and NLME was 'good' (ICC = 0.83; 95% CI [0.76, 0.88]).

Conclusion: For MRS, inter-rater reliability is excellent, even considering the possibility of noisy and/or incomplete data collected in low-vision individuals. For CPS, inter-rater reliability is lower. This may be problematic, for instance in the context of multisite investigations or follow-up examinations. The NLME method showed better agreement with the raters than the SDev method for both reading parameters. Setting up consensual guidelines to deal with ambiguous curves may help improve reliability. While the exact definition of CPS should be chosen on a case-by-case basis depending on the clinician or researcher's motivations, evidence suggests that estimating CPS as the smallest print size sustaining about 80% of MRS would increase inter-rater reliability.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Humans
  • Observer Variation
  • Reading*
  • Vision Disorders / physiopathology*
  • Vision Tests / methods*

Grants and funding

AFM and LHM were supported by the Portuguese Research Council grant reference PTDC/DPT-EPI/0412/2012 in the context of the Prevalence and Costs of Visual Impairment in Portugal: a hospital based study (PCVIP-study). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.