Tidal volume in mechanically ventilated dogs: can human strategies be extrapolated to veterinary patients?

J Vet Sci. 2019 May;20(3):e21. doi: 10.4142/jvs.2019.20.e21.

Abstract

This paper compares and describes the tidal volume (Vt) used in mechanically ventilated dogs under a range of clinical conditions. Twenty-eight dogs requiring mechanical ventilation (MV) were classified into 3 groups: healthy dogs mechanically ventilated during surgery (group I, n = 10), dogs requiring MV due to extra-pulmonary reasons (group II, n = 7), and dogs that required MV due to pulmonary pathologies (group III, n = 11). The median Vt used in each group was 16 mL/kg (interquartile range [IQR], 15.14-21) for group I, 12.59 mL/kg (IQR, 9-14.25) for group II, and 12.59 mL/kg (IQR, 10.15-14.96) for group III. The Vt used was significantly lower in group III than in group I (p = 0.016). The thoraco-pulmonary compliance was significantly higher in group I than in groups II and III (p = 0.011 and p = 0.006, respectively). The median driving pressure was similar among the groups with a median of 9, 11, and 10 cmH₂O in groups I, II, and III, respectively (p = 0.260). Critically-ill dogs requiring MV due to the primary pulmonary pathology received a significantly lower Vt than healthy dogs but with a range of values that were markedly higher than those recommended by human guidelines.

Keywords: Compliance; Ventilator-induced lung injury; mechanical ventilation; tidal volume.

Publication types

  • Comparative Study

MeSH terms

  • Animals
  • Dogs
  • Humans
  • Lung Diseases / therapy
  • Lung Diseases / veterinary*
  • Pressure
  • Respiration, Artificial / methods*
  • Tidal Volume