Role of cardiovascular magnetic resonance end-systolic 3D-SSFP sequence in repaired tetralogy of Fallot patients eligible for transcatheter pulmonary valve implantation

Int J Cardiovasc Imaging. 2019 Aug;35(8):1525-1533. doi: 10.1007/s10554-019-01630-9. Epub 2019 Jun 3.

Abstract

To evaluate the usefulness of cardiovascular magnetic resonance (CMR) 3D steady state free precession (SSFP) sequence acquired at end-systole (ES) in repaired Tetralogy of Fallot (rToF) patients eligible for percutaneous pulmonary valve implantation (PPVI). Between 2012 and 2018, 78 rToF patients were selected for pulmonary valve replacement (PVR) according to CMR criteria. CMR protocol included 3D-SSFP sequence used to assess the right ventricle outflow tract (RVOT) diameters at three levels (pulmonary valve remnant, mid-portion, bifurcation) in mid-diastole (MD) or ES, RVOT length and coronary artery anatomy. In 20 rToF patients without indications for PVR (controls), 3D SSFP sequence was acquired at both cardiac phases (MD and ES) to evaluate RVOT dimension throughout the cardiac cycle. Invasive balloon sizing was recorded in patients undergoing PPVI. The 3D-SSFP sequence was performed in MD on 39 patients and in ES on other 39, of whom 26 patients met the criteria for PPVI. The latter was unsuccessful in ten patients (38%), mainly due (80% of cases) to significant size discrepancy at PV remnant and bifurcation levels (p = 0.019 and 0.037 respectively) between the measurements by 3D-SSFP in MD and those by the balloon size in systole. Significant RVOT size difference between MD and ES was present at mid-portion and bifurcation levels in the PVR candidate group, and at all three-levels in the control group (all p < 0.001). ES 3D-SSFP sequence is able to quantify RVOT dilation in rToF patients at its maximum expansion, thus improving selection of PPVI candidates.

Keywords: 3D-SSFP navigator sequence; Cardiovascular magnetic resonance; Percutaneous pulmonary valve; Tetralogy of Fallot.

MeSH terms

  • Adolescent
  • Balloon Valvuloplasty
  • Cardiac Catheterization / instrumentation
  • Cardiac Catheterization / methods*
  • Cardiac Surgical Procedures* / adverse effects
  • Child
  • Clinical Decision-Making
  • Female
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / methods*
  • Hemodynamics*
  • Humans
  • Image Interpretation, Computer-Assisted
  • Magnetic Resonance Imaging, Cine*
  • Male
  • Observer Variation
  • Patient Selection
  • Predictive Value of Tests
  • Prosthesis Design
  • Pulmonary Circulation*
  • Pulmonary Valve Insufficiency / diagnostic imaging*
  • Pulmonary Valve Insufficiency / etiology
  • Pulmonary Valve Insufficiency / physiopathology
  • Pulmonary Valve Insufficiency / surgery
  • Reproducibility of Results
  • Retrospective Studies
  • Tetralogy of Fallot / diagnostic imaging
  • Tetralogy of Fallot / physiopathology
  • Tetralogy of Fallot / surgery*
  • Treatment Outcome
  • Young Adult