Cryoglobulins Today: Detection and Immunologic Characteristics of 1,675 Positive Samples From 13,439 Patients Obtained Over Six Years

Arthritis Rheumatol. 2019 Nov;71(11):1904-1912. doi: 10.1002/art.41003. Epub 2019 Sep 20.

Abstract

Objective: Cryoglobulins are cold-precipitating immunoglobulins. Through progress in techniques, we undertook this study to update information on the biologic characteristics of cryoglobulins in a very large population.

Methods: A cohort of 13,439 patients was tested for cryoglobulins from January 2010 to December 2016. The analysis included cryoglobulin isotype, clonality, concentration, and IgM rheumatoid factor (IgM-RF) in cryoprecipitate, as well as serum complement and RF. Markers of gammopathy, viral infection, and autoimmunity were also investigated.

Results: Of the 13,439 patients, 1,675 (12.5%) tested positive for cryoglobulins: 155 patients (9.3%) with type I, 788 (47%) with type II, and 732 (43.7%) with type III cryoglobulins. Nine percent of patients who were retested after initially testing negative for cryoglobulins showed a positive result on a follow-up test (196 of the 2,213 retested patients). In type I cryoglobulins, IgM was more frequent but occurred at lower concentrations than IgG. Mixed cryoglobulins were found in 34.8% of the tested patients who were positive for hepatitis C virus and <5% of those who were positive for hepatitis B virus or HIV. Of the patients with anti-double-stranded DNA, anti-SSA, or anti-cyclic citrullinated peptide autoantibodies, 25.4% tested positive for mixed cryoglobulins, with type III occurring more frequently than type II. Both cryoprecipitate and serum were RF-positive in 21.6% of type II and 10.1% of type III cryoglobulins. A decrease of C4, with or without accompanying decreases of C3 and CH50, was found in 23.6% of cryoglobulin samples.

Conclusion: Obtained with the use of modern assays, our findings from this very large collection of cryoglobulins provide an update on cryoglobulin distribution and characteristics, with minimal selection bias. Despite strict preanalytical conditions, a negative finding for the presence of cryoglobulin must be confirmed in a second sample. RF activity and complement decreases were rarely detected.

MeSH terms

  • Adult
  • Aged
  • Anti-Citrullinated Protein Antibodies / immunology*
  • Antibodies, Antinuclear / immunology*
  • Cohort Studies
  • Complement C3 / immunology
  • Complement C4 / immunology
  • Complement Hemolytic Activity Assay
  • Complement System Proteins / immunology*
  • Cryoglobulinemia / complications
  • Cryoglobulinemia / immunology*
  • Cryoglobulins / immunology*
  • Female
  • HIV Infections / complications
  • HIV Infections / immunology
  • Hepatitis B / complications
  • Hepatitis B / immunology
  • Hepatitis C / complications
  • Hepatitis C / immunology
  • Humans
  • Immunoglobulin M / immunology*
  • Lymphoproliferative Disorders / complications
  • Lymphoproliferative Disorders / immunology
  • Male
  • Middle Aged
  • Retrospective Studies
  • Rheumatoid Factor / immunology*

Substances

  • Anti-Citrullinated Protein Antibodies
  • Antibodies, Antinuclear
  • Complement C3
  • Complement C4
  • Cryoglobulins
  • Immunoglobulin M
  • SS-A antibodies
  • Complement System Proteins
  • Rheumatoid Factor