Background: Safe placement of pedicle screws without jeopardizing neurovascular structures medially and anteriorly is important during spine surgery. Inferior breach of pedicle is also dangerous due to low margin of error. Lumbar morphology and identical pedicle orientation at L1 to L5 shown on CT scan of young Taiwanese patients (90 patients) were analyzed and compared with findings reported for Caucasian subjects.
Methods: Previously reported techniques were employed to quantitatively elucidate the parameters regarding lumbar morphology and identical pedicle orientation at each vertebra. The parameters for pedicle angle (PA), pedicle diameter (PD), pedicle axis distance (PAD), midline axis distance (MAD), transverse pedicle axis distance (TPAD) and transverse intertangential angle (TITA) were measured.
Results: Taiwanese subjects had different PA, PD, PAD, MAD at L1 to L5 and TITA at L3 to L5 compared with Caucasian subjects. L5 had the most convergent pedicle axis, the widest PD and the shortest antero-posterior axis morphology.
Conclusions: This study provides detailed information for identifying pedicle orientation during pedicle screw placement and elucidate racial differences in lumbar morphology and pedicle orientation between Taiwanese and Caucasian populations.
Keywords: Anatomic study; Pedicle screws; Racial difference; Roy-Camille method; Weinstein method.