Evaluation of a Bi-Planar Robot Navigation System for Insertion of Cannulated Screws in Femoral Neck Fractures

Orthop Surg. 2019 Jun;11(3):373-379. doi: 10.1111/os.12450. Epub 2019 May 23.

Abstract

Objective: To evaluate the bi-planar robot navigation system for insertion of cannulated screws in femoral neck fractures.

Method: Between January 2016 and December 2016, 60 patients with femoral neck fractures were separately treated using percutaneous cannulated screws assisted by the bi-planar robot navigation system (robot group) and conventional freehand surgery (freehand group). The fluoroscopy time, the number of drilling attempts, and the operation time were recorded during operations; the dispersion and parallelism of the cannulated screws on the posteroanterior and lateral images were measured after operations. Patients were followed up for 12-24 months and the Harris scores and the final results of the two groups were compared.

Results: During bi-planar robot navigation system-assisted surgery, the fluoroscopy time for acquisition of images was 2.3 seconds on average, and the time for planning screws during the operation was 2.8 min on average. The average fluoroscopy time during the placement of the guide pin was 5.7 seconds and 14.14 seconds (P = 0.00), respectively. The average time of the placement of the cannulated screws was 12.7 min and 19.4 min (P = 0.00), respectively, in the robot group and the freehand group. In the robot group, only one guide pin was replaced during the operation, and the average number of adjustments for each guide pin was 2.39 in the freehand group. The screw parallelism and dispersion measured by postoperative imaging in the robot group were significantly superior to those in the freehand group. From postoperative CT it was evident that there were 5 cases of screws exiting the posterior cortex in both groups. During the follow-up phase, 1 case of femoral head necrosis and 5 cases of femoral neck shortening of more than 10 mm occurred in the robotic navigation group; 3 cases of femoral head necrosis, 1 case of fracture nonunion, and 2 cases of shortening of more than 10 mm occurred in the freehand group. At 18 months after surgery, the average Harris scores of the patients were 85.20 and 83.45, respectively, with no significant difference.

Conclusion: Using bi-planar robot navigation system-assisted placement of femoral neck cannulated screws can significantly reduce the time of intraoperative fluoroscopy, drilling attempts, and operation time. The placed screws are superior to the screws placed freehand in relation to parallelism and dispersion. However, it is still necessary for surgeons to have a good reduction of the femoral neck fracture before surgery and to be proficient in the operation of the robot navigation system. In summary, the bi-planar robot navigation system is an effective assistant instrument for surgery.

Keywords: Bi-planar robot navigation system; Cannulated screw fixation; Femoral neck fractures.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Bone Screws*
  • Female
  • Femoral Neck Fractures / diagnostic imaging
  • Femoral Neck Fractures / surgery*
  • Follow-Up Studies
  • Fracture Fixation, Internal / instrumentation
  • Fracture Fixation, Internal / methods*
  • Humans
  • Male
  • Middle Aged
  • Retrospective Studies
  • Robotic Surgical Procedures / instrumentation
  • Robotic Surgical Procedures / methods*
  • Tomography, X-Ray Computed
  • Treatment Outcome