A novel model for ex situ reperfusion of the human liver following subnormothermic machine perfusion

Technology (Singap World Sci). 2017 Dec;5(4):196-200. doi: 10.1142/S2339547817500108. Epub 2017 Nov 10.

Abstract

Machine perfusion-based organ preservation techniques are prudently transitioning into clinical practice. Although experimental data is compelling, the outcomes in the highly variable clinical donation-transplantation setting are unpredictable. Here, we offer an intermediate tool for pre-clinical assessment of human donor livers. We present a model for ex situ reperfusion of discarded human livers and report on its application in three human livers that have undergone subnormothermic (21°C) machine perfusion as an experimental preservation method. During reperfusion, the livers macroscopically reperfused in the first 15 minutes, and remained visually well-perfused for 3 hours of ex situ reperfusion. Bile production and oxygen consumption were observed throughout ex situ reperfusion. ATP levels increased 4.25-fold during SNMP. Between the end of SNMP and the end of reperfusion ATP levels dropped 45%. ALT levels in blood increased rapidly in the first 30 minutes and ALT release continued to taper off towards the end of perfusion. Release of CRP, TNF-α, IL-1β, and IL-12, IFN-γ was sustained during reperfusion. These findings support the use of this model for the evaluation of novel human liver preservation techniques.

Keywords: Biopreservation; Ischemia; Liver Transplantation; Machine Perfusion; Organ Preservation; Reperfusion.