Graphene Nanobuds: A New Second-Generation Phosgene Sensor with Ultralow Detection Limit in Aqueous Solution

ACS Appl Mater Interfaces. 2019 May 29;11(21):19339-19349. doi: 10.1021/acsami.9b02911. Epub 2019 May 15.

Abstract

Selective and sensitive detection of highly toxic chemicals by a suitable, fast, inexpensive, and trustworthy method is vital due to its serious health threats to humankind and breach of public security caused by unexpected terrorist attacks and industrial accidents. Phosgene or carbonyl dichloride is widely employed in many chemical industries and pharmaceuticals, and in pesticide production, which is extremely toxic by severe (short-term) inhalation exposure. Because of the non-existence of a phosgene sensor in aqueous solution and the immense emphasis gained by nanomaterials, especially carbonaceous materials, augmented attention has been given to the development of a fluorophore-functionalized carbon-based method to detect this noxious substance. In this study, surfactant free 1,8-diaminonaphthalene (DAN)-functionalized graphene quantum dots (DAN-GQDs) were prepared to detect phosgene in aqueous solution. The FESEM (field emission scanning electron microscopy) and HRTEM (high-resolution transmission electron microscopy) analyses confirm the as-prepared DAN-GQD morphology as nanobuds (NBs) with an average diameter of ca. 35-40 nm. The crystalline nature, elemental composition, and chemical state of DAN-GQDs were analyzed by standard physiochemical techniques. The edge-termination at the carboxyl functional group of GQDs with DAN was examined by XPS, Raman, FT-IR, and 1H NMR spectroscopy analyses. The aqueous solution of DAN-GQDs (4.89 × 10-9 M) exhibits a strong emission peak at 423 nm upon excitation at 328 nm. The addition of the phosgene molecule (0 → 88 μL) quenches the initial fluorescence intensity of DAN-GQDs (ΦF 53.6 → 34.6%) through the formation of a stable six-membered cyclized product. The DAN-GQDs displayed excellent selectivity and sensitivity for phosgene ( Ka = 3.84 × 102 M-1 and LoD (limit of detection) = 2.26 ppb) over other competing toxic pollutants in water. The time-resolved fluorescence analysis confirms that the quenching of DAN-GQDs follows nonradiative relaxation of excited electrons. Furthermore, bioimaging experiments of phosgene in living human breast cancer (HeLa) cells and cell viability test successfully demonstrated the practicability of DAN-GQDs.

Keywords: bioimaging; cytotoxicity; graphene nanobuds; phosgene; ultralow detection limit.