Is MRCP necessary to diagnose pancreas divisum?

BMC Med Imaging. 2019 Apr 29;19(1):33. doi: 10.1186/s12880-019-0329-1.

Abstract

Background: The purpose of this study is to compare the performance of three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with non-MRCP T2-weighted magnetic resonance imaging (MRI) sequences for diagnosis of pancreas divisum (PD).

Methods: This is a retrospective study of 342 consecutive patients with abdominal MRI including 3D-MRCP. 3D-MRCP was a coronal respiration-navigated T2-weighted sequence with 1.5 mm slice thickness. Non-MRCP T2-weighted sequences were (1) a coronal inversion recovery sequence (TIRM) with 6 mm slice thickness and (2) a transverse single shot turbo spin echo sequence (HASTE) with 4 mm slice thickness. For 3D-MRCP, TIRM, and HASTE, presence of PD and assessment of evaluability were determined in a randomized manner. A consensus read by two radiologists using 3D-MRCP, non-MRCP T2-weighted sequences, and other available imaging sequences served as reference standard for diagnosis of PD. Statistical analysis included performance analysis of 3D-MRCP, TIRM, and HASTE and testing for noninferiority of non-MRCP T2-weighted sequences compared with 3D-MRCP.

Results: Thirty-three of 342 patients (9.7%) were diagnosed with PD using the reference standard. Sensitivity/specificity of 3D-MRCP for detecting PD were 81.2%/69.7% (p < 0.001). Sensitivity/specificity of TIRM and HASTE were 92.5%/93.9 and 98.1%/97.0%, respectively (p < 0.001 each). Grouped sensitivity/specificity of non-MRCP T2-weighted sequences were 99.8%/91.0%. Non-MRCP T2-weighted sequences were non-inferior to 3D-MRCP alone for diagnosis of PD. 20.2, 7.3%, and 2.3% of 3D-MRCP, TIRM, and HASTE, respectively, were not evaluable due to motion artifacts or insufficient duct depiction.

Conclusions: Non-MRCP T2-weighted MRI sequences offer high performance for diagnosis of PD and are noninferior to 3D-MRCP alone.

Trial registration: Not applicable.

Keywords: HASTE; MRCP; MRI; Pancreas divisum; TIRM.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Cholangiopancreatography, Magnetic Resonance / methods*
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted
  • Male
  • Middle Aged
  • Pancreas / abnormalities*
  • Pancreas / diagnostic imaging
  • Retrospective Studies
  • Sensitivity and Specificity