Influence of implant neck and abutment characteristics on peri-implant tissue health and stability. Oral reconstruction foundation consensus report

Clin Oral Implants Res. 2019 Jun;30(6):588-593. doi: 10.1111/clr.13439. Epub 2019 May 14.

Abstract

Objective: The aim of this consensus meeting was to assess the influence of implant neck and abutment characteristics on peri-implant tissue health and stability.

Material and methods: Group and plenary discussions were based on two systematic reviews focusing on the effect of titanium implants with different collar designs/surface modifications and the abutment material on the stability of marginal bone levels (MBLs), peri-implant health, and survival rates.

Results: The changes in MBLs were not influenced by the abutment material and were also similar at one- and two-piece implants after one year of loading. Rough collar implants improved MBLs in comparison to machined collar implants. Additional modifications of the collar had no beneficial clinical effect on MBLs. Titanium abutments were associated with significantly higher increases in bleeding on probing when compared with zirconia abutments.

Conclusion: MBLs are mainly influenced by the microstructure (i.e., rough surfaced) of the implant neck. Consensus statements and specific recommendations for future research were elaborated during the consensus meeting.

Keywords: bone-implant interactions; clinical trials; soft tissue-implant interactions.

MeSH terms

  • Consensus
  • Dental Abutments*
  • Dental Implants*
  • Titanium

Substances

  • Dental Implants
  • Titanium