Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics

BMJ Open. 2019 Apr 2;9(4):e022278. doi: 10.1136/bmjopen-2018-022278.

Abstract

Objectives: This study aimed to identify the incidence of and factors associated with peripheral intravenous catheter/cannula (PIVC) first time insertion success (FTIS) in the emergency department (ED).

Design: Prospective cohort study.

Setting: Two tertiary EDs in Western Australia.

Participants: 879 ED patients.

Primary outcome: To identify factors affecting FTIS using univariate and multivariate logistic regression modelling. We created four models: patient factors only; clinician factors only; products and technology factors only and all factors model. We assessed each model's performance using area under the receiver operating characteristic curve.

Results: A total of 1201 PIVCs were inserted in 879 patients. The mean age was 60.3 (SD 22) years with slightly more females (52%). The FTIS rate was 73%, with 128 (15%) requiring a second attempt and 83 (9%) requiring three or more attempts. A small percentage (3%) had no recorded number of subsequent attempts. FTIS was related to the following patient factors: age (for a 1-year increase in age: OR 0.99, 95% CI 0.983 to 0.998; p=0.0097); and target vein palpability: (always palpable vs never palpable: OR 3.53 95% CI 1.64 to 7.60; only palpable with tourniquet vs never palpable: OR 2.20, 95% CI 1.06 to 4.57; p=0.0014). Clinician factors related to FTIS include: clinicians with greater confidence (p<0.0001) and insertion experience (301-1000 vs <301: OR 1.54, 95% CI 1.02 to 2.34; >1000 vs <301: OR 2.07, 95% CI 1.41 to 3.04; p=0.0011). The final all factors model combining patient factors; clinician factors and product and technology factors has greater discriminative ability than specific factors models. It has a sensitivity of 74.26%, specificity of 57.69%, positive predictive value of 82.87% and negative predictive value of 44.85%.

Conclusion: A clinical decision, matching patients who have no palpable veins and are older, with clinicians with greater confidence and experience, will likely improve FTIS.

Trialregistration number: ANZCTRN12615000588594; Results.

Keywords: emergency department; first time insertion success; logistic regression; peripheral intravenous catheters; receiver-operator characteristic curve.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Catheterization, Peripheral / adverse effects
  • Catheterization, Peripheral / instrumentation*
  • Catheters, Indwelling*
  • Central Venous Catheters*
  • Emergency Service, Hospital*
  • Equipment Design
  • Female
  • Humans
  • Logistic Models
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Predictive Value of Tests
  • Prospective Studies
  • Risk Factors
  • Sensitivity and Specificity
  • Treatment Failure
  • Western Australia

Associated data

  • ANZCTR/ANZCTRN12615000588594