12-Month clinical results of drug-coated balloons for de novo coronary lesion in vessels exceeding 3.0 mm

Int J Cardiovasc Imaging. 2019 Apr;35(4):579-586. doi: 10.1007/s10554-018-1505-z. Epub 2019 Mar 30.

Abstract

The purpose of this observational study was to investigate the feasibility, initial safety, and efficacy of the SeQuent® Please DCB (B. Braun Melsungen, Germany) for patients with de novo coronary lesions in vessels exceeding 3.0 mm in a consecutive series of all comer percutaneous coronary intervention. A total of 120 patients (135 lesions) with de novo coronary lesions in vessels ≥ 3.0 mm treated with DCB were enrolled in this single-centre prospective observational study. The primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac death, target vessel-myocardial infarction (TV-MI), and clinically driven target vessel revascularization (TLR) at 12 months. Safety endpoints included cardiac death, TV-MI, and definite target vessel thrombosis. 45.9% of the lesions were classified as complex (type B2/C). The reference vessel diameter was 3.09 ± 0.31 mm measured via quantitative coronary angiography analysis. Coronary dissections occurred in 42 patients (35.0%; Type A-B 14.1%; Type C 19.1%; Type D: 1.6%), two of which [1.6%; (type D dissection)] underwent bail-out stent implantation. 12-month follow-up was completed in 100% patients. The 12-month incidence of TLF was 3.4%. The clinically driven TLR occurred in four patients (3.4%). The incidence of TLR was low in patients without any detectable dissections, similar to those with dissections (3.8% vs. 2.5%; p = 0.146). No patient suffered cardiac death, TV-MI, or target vessel thrombosis. The study shows the feasibility, initial safety, and efficacy of coronary intervention using SeQuent® Please DCB for the treatment of patients with de novo lesion in vessels exceeding 3 mm. The study highlights that the coronary dissection (Type A-C) post DCB treatment occurs frequently but is safe at follow up.

Keywords: Coronary dissection; De novo; Drug-coated balloon; Target lesion failure.

Publication types

  • Observational Study

MeSH terms

  • Aged
  • Cardiac Catheters*
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Coated Materials, Biocompatible*
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / surgery*
  • Coronary Stenosis / diagnostic imaging
  • Coronary Stenosis / mortality
  • Coronary Stenosis / surgery*
  • Equipment Design
  • Feasibility Studies
  • Female
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Paclitaxel / administration & dosage*
  • Paclitaxel / adverse effects
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Postoperative Complications / mortality
  • Postoperative Complications / surgery
  • Prospective Studies
  • Risk Factors
  • Time Factors
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Coated Materials, Biocompatible
  • Paclitaxel