Effect of Bubble Concentration on the in Vitro and in Vivo Performance of Highly Stable Lipid Shell-Stabilized Micro- and Nanoscale Ultrasound Contrast Agents

Langmuir. 2019 Aug 6;35(31):10192-10202. doi: 10.1021/acs.langmuir.9b00462. Epub 2019 Apr 9.

Abstract

Ultrasound (US) is a widely used diagnostic imaging tool because it is inexpensive, safe, portable, and broadly accessible. Ultrasound contrast agents (UCAs) are employed to enhance backscatter echo and improve imaging contrast. The most frequently utilized UCAs are echogenic bubbles made with a phospholipid or protein-stabilized hydrophobic gas core. While clinically utilized, applications of UCAs are often limited by rapid signal decay (<5 min) in vivo under typical ultrasound imaging protocols. Here, we report on a formulation of lipid shell-stabilized perfluoropropane (C3F8) microbubbles and nanobubbles with a significantly prolonged in vivo stability. Microbubbles (875 ± 280 nm) of the target size were prepared by utilizing a multiple-step centrifugation cycle, while nanobubbles (299 ± 189 nm) were isolated from the activated vial using a single centrifugation step. To provide in-depth acoustic characterization of the new construct we evaluated the effect of size and concentration on their in vitro and in vivo performance. In vitro and in vivo characterization were carried out for a range of bubble concentrations normalized by total gas volume quantified via headspace gas chromatography/mass spectrometry (GC/MS). In vitro characterization revealed that nanobubbles at different concentrations are more consistently stable over time with the highest and lowest dilutions (50-fold decrease) only differing in US signal after 8 min exposure by 10.34%, while for microbubbles the difference was 86.46%. As expected, due to the difference in hydrodynamic diameter and scattering cross section difference, nanobubbles showed lower overall initial signal intensity. In vivo experiments showed that both microbubbles and nanobubbles with similar initial peak signal intensity are comparably stable over time with 66.8% and 60.6% remaining signal after 30 min, respectively. This study demonstrates that bubble concentration has significant effects on the persistence of both microbubbles and nanobubbles in vitro and in vivo, but the effects are more pronounced in larger bubbles. These effects should be taken into account when selecting the appropriate bubble parameters for future imaging applications.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Animals
  • Contrast Media / chemistry*
  • Fluorocarbons / chemistry
  • Kidney / diagnostic imaging
  • Mice
  • Microbubbles*
  • Nanostructures / chemistry*
  • Particle Size
  • Phosphatidic Acids / chemistry
  • Phosphatidylcholines / chemistry
  • Phosphatidylethanolamines / chemistry
  • Ultrasonography / methods

Substances

  • Contrast Media
  • Fluorocarbons
  • Phosphatidic Acids
  • Phosphatidylcholines
  • Phosphatidylethanolamines
  • dipalmitoylphosphatidic acid
  • 1,2-dipalmitoyl-3-phosphatidylethanolamine
  • perflutren