Radiation Contamination Following Cremation of a Deceased Patient Treated With a Radiopharmaceutical

JAMA. 2019 Feb 26;321(8):803-804. doi: 10.1001/jama.2018.21673.

Abstract

This case report describes contamination of crematory equipment with lutetium Lu 177 after cremation of a patient with a pancreatic neuroendocrine tumor treated with the radioisotope 2 days prior to his death.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Air Pollutants, Radioactive / analysis
  • Carcinoma, Neuroendocrine / radiotherapy
  • Cremation*
  • Environmental Exposure / analysis*
  • Humans
  • Male
  • Occupations
  • Octreotide / analogs & derivatives*
  • Octreotide / analysis
  • Octreotide / therapeutic use
  • Organometallic Compounds / analysis*
  • Organometallic Compounds / therapeutic use
  • Pancreatic Neoplasms / radiotherapy
  • Radiation Exposure / analysis*
  • Radiometry*
  • Radiopharmaceuticals / analysis*
  • Radiopharmaceuticals / therapeutic use
  • Technetium / analysis

Substances

  • Air Pollutants, Radioactive
  • Organometallic Compounds
  • Radiopharmaceuticals
  • Technetium
  • lutetium Lu 177 dotatate
  • Octreotide