Comparison between dynamic gadoxetate-enhanced MRI and 99mTc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function

Eur Radiol. 2019 Sep;29(9):5063-5072. doi: 10.1007/s00330-019-06029-7. Epub 2019 Feb 22.

Abstract

Objectives: To compare Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) with 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) as quantitative liver function tests for the preoperative assessment of patients undergoing liver resection.

Methods: Patients undergoing liver surgery and preoperative assessment of future remnant liver (FRL) function using 99mTc-mebrofenin HBS were included. Patients underwent DHCE-MRI. Total liver uptake function was calculated for both modalities: mebrofenin uptake rate (MUR) and Ki respectively. The FRL was delineated with both SPECT-CT and MRI to calculate the functional share. Blood samples were taken to assess biochemical liver parameters.

Results: A total of 20 patients were included. The HBS-derived MUR and the DHCE-MRI-derived mean Ki correlated strongly for both total and FRL function (Pearson r = 0.70, p = 0.001 and r = 0.89, p < 0.001 respectively). There was a strong agreement between the functional share determined with both modalities (ICC = 0.944, 95% CI 0.863-0.978, n = 20). There was a significant negative correlation between liver aminotransferases and bilirubin for both MUR and Ki.

Conclusions: Assessment of liver function with DHCE-MRI is comparable with that of 99mTc-mebrofenin HBS and has the potential to be combined with diagnostic MRI imaging. This can therefore provide a one-stop-shop modality for the preoperative assessment of patients undergoing liver surgery.

Key points: • Quantitative assessment of liver function using hepatobiliary scintigraphy is performed in the preoperative assessment of patients undergoing liver surgery in order to prevent posthepatectomy liver failure. • Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) is an emerging method to quantify liver function and can serve as a potential alternative to hepatobiliary scintigraphy. • Assessment of liver function with dynamic gadoxetate-enhanced MRI is comparable with that of hepatobiliary scintigraphy and has the potential to be combined with diagnostic MRI imaging.

Keywords: Gadolinium ethoxybenzyl DTPA; Liver function tests; Magnetic resonance imaging; Technetium Tc 99m mebrofenin.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Aged
  • Female
  • Gadolinium DTPA / pharmacology*
  • Hepatectomy
  • Humans
  • Liver / diagnostic imaging*
  • Liver Diseases / diagnosis*
  • Liver Diseases / surgery
  • Liver Function Tests / methods
  • Magnetic Resonance Imaging / methods
  • Male
  • Middle Aged
  • Pilot Projects
  • Prospective Studies
  • Radionuclide Imaging / methods*
  • Radiopharmaceuticals / pharmacology
  • Tomography, Emission-Computed, Single-Photon / methods*

Substances

  • Radiopharmaceuticals
  • gadolinium ethoxybenzyl DTPA
  • Gadolinium DTPA