Which Parameters Affect Biofilm Removal with Acoustic Cavitation? A Review

Ultrasound Med Biol. 2019 May;45(5):1044-1055. doi: 10.1016/j.ultrasmedbio.2019.01.002. Epub 2019 Feb 19.

Abstract

Bacterial biofilms are a cause of contamination in a wide range of medical and biological areas. Ultrasound is a mechanical energy that can remove these biofilms using cavitation and acoustic streaming, which generate shear forces to disrupt biofilm from a surface. The aim of this narrative review is to investigate the literature on the mechanical removal of biofilm using acoustic cavitation to identify the different operating parameters affecting its removal using this method. The properties of the liquid and the properties of the ultrasound have a large impact on the type of cavitation generated. These include gas content, temperature, surface tension, frequency of ultrasound and acoustic pressure. For many of these parameters, more research is required to understand their mechanisms in the area of ultrasonic biofilm removal, and further research will help to optimise this method for effective removal of biofilms from different surfaces.

Keywords: Biofilm cavitation; Biofilm disruption; Biofilm removal; Ultrasonic cleaning.

Publication types

  • Research Support, Non-U.S. Gov't
  • Review

MeSH terms

  • Acoustics
  • Biocompatible Materials
  • Biofilms / growth & development*
  • Dental Implants / microbiology*
  • Microscopy, Electron, Scanning
  • Surface Properties
  • Ultrasonic Waves*

Substances

  • Biocompatible Materials
  • Dental Implants