Behavior of two-chamber microbial electrochemical systems started-up with different ion-exchange membrane separators

Bioresour Technol. 2019 Apr:278:279-286. doi: 10.1016/j.biortech.2019.01.097. Epub 2019 Jan 23.

Abstract

In this study, microbial fuel cells (MFCs) - operated with novel cation- and anion-exchange membranes, in particular AN-VPA 60 (CEM) and PSEBS DABCO (AEM) - were assessed comparatively with Nafion proton exchange membrane (PEM). The process characterization involved versatile electrochemical (polarization, electrochemical impedance spectroscopy - EIS, cyclic voltammetry - CV) and biological (microbial structure analysis) methods in order to reveal the influence of membrane-type during start-up. In fact, the use of AEM led to 2-5 times higher energy yields than CEM and PEM and the lowest MFC internal resistance (148 ± 17 Ω) by the end of start-up. Regardless of the membrane-type, Geobacter was dominantly enriched on all anodes. Besides, CV and EIS measurements implied higher anode surface coverage of redox compounds for MFCs and lower membrane resistance with AEM, respectively. As a result, AEM based on PSEBS DABCO could be found as a promising material to substitute Nafion.

Keywords: Bioelectrochemical system; Membrane; Microbial community structure; Microbial fuel cell; Principal component analysis; Separator.

MeSH terms

  • Bioelectric Energy Sources
  • Electrochemical Techniques* / instrumentation
  • Electrodes
  • Fluorocarbon Polymers
  • Geobacter
  • Ion Exchange

Substances

  • Fluorocarbon Polymers
  • perfluorosulfonic acid