Objective: The purpose of this study was to explore the value of 3-T MRI for evaluating the preoperative T staging of esophageal cancer (EC) treated with neoadjuvant chemotherapy (NAC), with histopathologic confirmation.

Subjects and methods: This prospective study enrolled patients for whom endoscopic biopsy showed EC and pretreatment CT showed stage cT1N+M0 or cT2-T4aN0-N3M0. All patients received two cycles of NAC (paclitaxel and nedaplatin protocol) followed by 3-T MRI and surgical resection. Readers assigned a T category on MRI, and postoperative pathologic confirmation was considered the reference standard. Interreader agreement, the diagnostic accuracy of T staging on T2-weighted turbo spin-echo (TSE) BLADE (Siemens Healthcare), contrast-enhanced StarVIBE (Siemens Healthcare), high-resolution delayed phase StarVIBE, and the combination of the three sequences were analyzed and compared with postoperative pathologic T staging.

Results: The study included 79 patients. Mean time between NAC and MRI was 23 days. Interreader agreements of T category assignment were excellent for T2-weighted TSE BLADE (κ = 0.810, p < 0.0001), contrast-enhanced StarVIBE (κ = 0.845, p < 0.0001), high-resolution delayed phase StarVIBE (κ = 0.897, p < 0.0001), and the combination of the three sequences (κ = 0.880, p < 0.0001). The highest accuracy for T0, T1, T2, and T4a lesions was on high-resolution delayed phase StarVIBE (96.2%, 92.4%, 91.1%, and 91.1% for reader 1; 94.9%, 89.9%, 91.1%, and 94.9% for reader 2), and the highest accuracy for T3 lesions was on T2-weighted TSE BLADE (92.4% and 94.9% for reader 1 and reader 2, respectively). Diagnostic accuracy of the combination of the three sequences was not improved compared with individual sequences.

Conclusion: High-resolution delayed phase StarVIBE had the highest diagnostic accuracy in staging EC after NAC for all T categories except T3, for which T2-weighted TSE BLADE had the highest accuracy. Combining all three sequences did not improve diagnostic accuracy.

Keywords: MRI; esophageal cancer; neoadjuvant therapy; neoplasm staging.

MeSH terms

  • Adult
  • Aged
  • Chemotherapy, Adjuvant
  • Contrast Media
  • Esophageal Neoplasms / diagnostic imaging*
  • Esophageal Neoplasms / drug therapy*
  • Esophageal Neoplasms / pathology*
  • Female
  • Gadolinium DTPA
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Neoadjuvant Therapy
  • Neoplasm Staging
  • Organoplatinum Compounds / administration & dosage
  • Paclitaxel / administration & dosage
  • Prospective Studies

Substances

  • Contrast Media
  • Organoplatinum Compounds
  • nedaplatin
  • Gadolinium DTPA
  • Paclitaxel