Preliminary application of 3D-printed coplanar template for iodine-125 seed implantation therapy in patients with advanced pancreatic cancer

World J Gastroenterol. 2018 Dec 14;24(46):5280-5287. doi: 10.3748/wjg.v24.i46.5280.

Abstract

Aim: To evaluate a 3D-printed coplanar template for iodine-125 seed implantation therapy in patients with pancreatic cancer.

Methods: A retrospective analysis of our database was performed, and a total of 25 patients with pancreatic cancer who underwent iodine-125 seed implantation between January 2014 and November 2017 were analyzed. Of these, 12 implantations were assisted by a 3D-printed coplanar template (group A), and 13 implantations performed freehand were selected as a control group (group B). A 3D coplanar template was designed and printed according to a preoperative CT scan and treatment planning system. The iodine-125 seeds were then implanted using the template as a guide. Dosimetric verification was performed after implantation. Pre- and postoperative D90, V100, and V150 were calculated. The success rate of iodine-125 seed implantation, dosimetric parameters, and complications were analyzed and compared between the two groups.

Results: Iodine-125 seed implantation was successfully performed in both groups. In group A, the median pre- and postoperative D90 values were 155.32 ± 8.05 Gy and 154.82 ± 16.43 Gy, respectively; the difference between these values was minimal and not statistically significant (P > 0.05). Postoperative V100 and V150 were 91.05% ± 4.06% and 64.54% ± 13.40%, respectively, which met the treatment requirement. A better dosimetric parameter was observed in group A than in group B, and the difference was statistically significant (V100: 91.05% ± 4.06% vs 72.91% ± 13.78%, P < 0.05). No major procedure-related complications were observed in either group. For group A, mild hemorrhage was observed in 1 patient with a peritoneal local hematoma due to mesenteric vein damage from the iodine-125 seed implantation needle. The hematoma resolved spontaneously without treatment. Postoperative blood amylase levels remained within the normal range for all patients.

Conclusion: A 3D-printed coplanar template appears to be a safe and effective iodine-125 seed implantation guidance tool to improve implantation accuracy and optimize dosimetric distribution.

Keywords: 3D printing; Brachytherapy; Iodine-125; Pancreatic cancer.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Brachytherapy / adverse effects
  • Brachytherapy / instrumentation
  • Brachytherapy / methods*
  • Female
  • Humans
  • Iodine Radioisotopes / administration & dosage*
  • Male
  • Mesenteric Veins / injuries
  • Middle Aged
  • Needles / adverse effects
  • Pancreas / diagnostic imaging
  • Pancreas / pathology
  • Pancreatic Neoplasms / diagnostic imaging
  • Pancreatic Neoplasms / radiotherapy*
  • Printing, Three-Dimensional
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / adverse effects
  • Radiotherapy Planning, Computer-Assisted / methods*
  • Retrospective Studies
  • Tomography, X-Ray Computed
  • Treatment Outcome

Substances

  • Iodine Radioisotopes
  • Iodine-125