Head-to-head comparison of the diagnostic performances of Rubidium-PET and SPECT with CZT camera for the detection of myocardial ischemia in a population of women and overweight individuals

J Nucl Cardiol. 2020 Jun;27(3):755-768. doi: 10.1007/s12350-018-01557-z. Epub 2018 Dec 20.

Abstract

Background: The aim of this study was to compare the diagnostic performances for the detection of myocardial ischemia of 82-Rb-PET-MPS and 99m-Tc-SPECT-MPS in overweight individuals and women.

Methods and results: Men with BMI ≥ 25 and women referred for MPS were considered for inclusion. All individuals underwent 99m-Tc-SPECT-MPS with CZT cameras and 82-Rb-PET-MPS in 3D-mode. Individuals with at least one positive MPS were referred for coronary angiography (CA) with FFR measurements. A criterion for positivity was a composite endpoint including significant stenosis on CA or, in the absence of CA, the occurrence of acute coronary event during the following year. 313 patients (46% women) with mean BMI of 31.8 ± 6.5 were included. Sensitivity for the detection of myocardial ischemia was higher with 82-Rb-PET-MPS compared with 99m-Tc-SPECT-MPS (85% vs. 57%, P < .05); specificity was equally high with both imaging techniques (93% vs. 94%, P > .05). 82-Rb-PET allowed for a more accurate detection of patients with a high-risk coronary artery disease (HR-CAD) than 99m-Tc-SPECT-MPS (AUC = 0.86 vs. 0.75, respectively; P = .04).

Conclusions: In women and overweight individuals, 82-Rb-PET-MPS provides higher sensitivity for the detection of myocardial ischemia than 99m-Tc-SPECT-MPS thanks to a better image quality and an improved detection of HR-CAD.

Keywords: 82-Rubidium; CAD; CZT camera; Diagnostic and prognostic application; MPI; Myocardial blood flow; PET; SPECT.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Area Under Curve
  • Body Mass Index
  • Cadmium
  • Coronary Artery Disease / complications
  • Coronary Artery Disease / diagnostic imaging
  • Female
  • Humans
  • Image Processing, Computer-Assisted
  • Male
  • Middle Aged
  • Myocardial Ischemia / complications*
  • Myocardial Ischemia / diagnostic imaging*
  • Overweight / complications*
  • Overweight / diagnostic imaging*
  • Positron-Emission Tomography / methods*
  • Reproducibility of Results
  • Risk Factors
  • Rubidium*
  • Sensitivity and Specificity
  • Tellurium
  • Tomography, Emission-Computed, Single-Photon / methods*
  • Zinc

Substances

  • CdZnTe
  • Cadmium
  • Zinc
  • Rubidium
  • Tellurium