Determination of Tranquilizers in Swine Urine by Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry

Molecules. 2018 Dec 5;23(12):3215. doi: 10.3390/molecules23123215.

Abstract

A rapid, reliable, and sensitive method was developed for the determination of ten tranquilizers in swine urine. Sample preparation was based on solid-phase extraction, which combined isolation of the compounds and sample cleanup in a single step. Separation was performed on a reversed phase C18 column by gradient elution with a chromatographic run time of seven minutes, consisting of 0.1% formic acid in water and acetonitrile as the mobile phase. Multiple reaction monitoring in positive mode was applied for data acquisition. Matrix-matched calibration was used for quantification and good linearity was obtained with coefficients of determination higher than 0.99. The average recoveries of fortified samples at concentrations between 0.05 and 10 µg/L ranged from 85% to 106% with interday relative standard deviations of less than 13% in all cases. The limits of detection and limits of quantification obtained for tranquilizers in the urine were in the ranges of 0.03⁻0.1 µg/L and 0.05⁻0.25 µg/L, respectively. The applicability of the proposed method was demonstrated by analyzing real samples; diazepam was detected at concentrations between 0.3 and 0.6 μg/L.

Keywords: MS/MS; UHPLC; swine urine; tranquilizers.

MeSH terms

  • Animals
  • Chromatography, High Pressure Liquid
  • Chromatography, Liquid
  • Liquid-Liquid Extraction
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Swine
  • Tandem Mass Spectrometry
  • Tranquilizing Agents / chemistry*
  • Tranquilizing Agents / isolation & purification
  • Tranquilizing Agents / urine*

Substances

  • Tranquilizing Agents