Lymphangiography and Post-lymphangiographic Multidetector CT for Preclinical Lymphatic Interventions in a Rabbit Model

Cardiovasc Intervent Radiol. 2019 Mar;42(3):448-454. doi: 10.1007/s00270-018-2123-9. Epub 2018 Nov 20.

Abstract

Purpose: To describe the feasibility of lymphangiography and the visibility of the lymphatic system using post-lymphangiographic multidetector CT (MDCT) for preclinical lymphatic interventions in a rabbit model.

Materials and methods: Lymphangiography via the popliteal lymph node or vessel after surgical exposure was performed, using six healthy female Japanese White rabbits. Lipiodol was manually injected for lymphangiography. Post-lymphangiographic MDCT examinations were performed in all rabbits. The dataset images were subjected to image processing analysis utilizing the three-dimensional maximum intensity projection technique. Three reviewers evaluated the degree of depiction of the lymphatic system using a four-point visual score (1, poor; 2, fair; 3, good; 4, excellent). The distance between the body surface and cisterna chyli was measured on post-lymphangiographic MDCT axial image.

Results: Lymphangiography was successfully performed in all rabbits. The popliteal lymph node was detectable in 90%. The visualization of lymphatic system via the popliteal node was achieved in 89%. Mean visual scores of > 3.0 were realized by the right femoral lymphatic vessel, left femoral lymphatic vessel, left iliac lymphatic vessel, left lumbar lymphatic trunks and cisterna chyli, whereas mean visual scores of < 3.0 were yielded by the right iliac lymphatic vessel, right lumbar lymphatic trunks and thoracic duct. The distance between the body surface and cisterna chyli on post-lymphangiographic MDCT axial images was 4.33 ± 0.14 cm.

Conclusion: Lymphangiography is feasible, and the visibility of the lymphatic system on post-lymphangiographic MDCT in a rabbit model provides enough information for interventional radiologists to perform preclinical lymphatic interventions.

Keywords: Lipiodol; Lymphangiography; Lymphatic interventions; Post-lymphangiographic multidetector CT.

MeSH terms

  • Animals
  • Contrast Media
  • Ethiodized Oil
  • Feasibility Studies
  • Female
  • Humans
  • Imaging, Three-Dimensional / methods
  • Lymphatic System / diagnostic imaging*
  • Lymphography / methods*
  • Models, Animal
  • Multidetector Computed Tomography / methods*
  • Rabbits
  • Radiographic Image Enhancement / methods
  • Reproducibility of Results

Substances

  • Contrast Media
  • Ethiodized Oil