Outcomes associated with a transcarotid artery revascularization-centered protocol in high-risk carotid revascularizations using the ENROUTE neuroprotection system

J Vasc Surg. 2019 Mar;69(3):807-813. doi: 10.1016/j.jvs.2018.06.222. Epub 2018 Oct 6.

Abstract

Objective: This investigation describes the perioperative and early follow-up results associated with transcarotid artery revascularization (TCAR) in patients not participating in the Safety and Efficacy Study for Reverse Flow Used During Carotid Artery Stenting Procedure II (ROADSTER-2) registry using the ENROUTE neuroprotection system (ENPS; Silk Road Medical, Sunnyvale, Calif).

Methods: A retrospective review was performed capturing all TCAR/ENPS procedures in patients deemed to be at high risk for complications after traditional carotid endarterectomy. All patients enrolled in the ROADSTER-2 registry were excluded, leaving only those treated outside trial regulations for analysis. Preoperative demographics, intraoperative variables, and perioperative and follow-up outcomes were abstracted and reported herein.

Results: From December 2015 to January 2018, there were 75 carotid arteries treated at our institution. All interventions were performed on carotid arteries that were symptomatic with ≥50% stenosis (46.7%) or asymptomatic with ≥80% stenosis (53.3%) by duplex ultrasound and computed tomography angiography. Technical success in our series was 97.3% (73/75), with treatment failures attributed to one case of common carotid artery dissection and another secondary to stent maldeployment in the external carotid artery. Perioperative (30-day) ipsilateral stroke rate was 2.7% (n = 2), myocardial infarction incidence was 0%, and mortality rate was 2.7% (n = 2). We did not observe any cranial nerve injuries. After a mean follow-up of 8.0 ± 6.7 months, no carotid stents required reintervention. However, we noted one instance of minor (<50%) in-stent stenosis and one asymptomatic stent thrombosis. One additional ipsilateral stroke was observed on follow-up, probably from a cardiac source.

Conclusions: We report that dynamic reverse-flow TCAR using the ENPS continues to be safe, feasible, and efficacious with minimal risks of postoperative stroke, myocardial infarction, and mortality outside of ROADSTER-2 regulations.

Keywords: Carotid revascularization; ENROUTE; Reverse flow; Stenting; Stroke; TCAR.

MeSH terms

  • Aged
  • Asymptomatic Diseases
  • Carotid Stenosis / diagnostic imaging
  • Carotid Stenosis / mortality
  • Carotid Stenosis / surgery*
  • Embolic Protection Devices*
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Endovascular Procedures / mortality
  • Female
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Myocardial Infarction / diagnosis
  • Myocardial Infarction / mortality
  • Myocardial Infarction / prevention & control*
  • Prosthesis Design
  • Protective Factors
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Severity of Illness Index
  • Stents*
  • Stroke / diagnosis
  • Stroke / mortality
  • Stroke / prevention & control*
  • Time Factors
  • Treatment Outcome