Anaesthetic management during intracranial mechanical thrombectomy: systematic review and meta-analysis of current data

J Neurol Neurosurg Psychiatry. 2019 Jan;90(1):68-74. doi: 10.1136/jnnp-2018-318549. Epub 2018 Sep 26.

Abstract

Objective: Our aim was to compare the clinical outcome of patients with ischaemic stroke with anterior large vessel occlusion treated with stent retrievers and/or contact aspiration mechanical thrombectomy (MT) under general anaesthesia (GA) or conscious sedation non-GA through a systematic review and meta-analysis.

Methods: The literature was searched using PubMed, Embase and Cochrane databases to identify studies reporting on anaesthesia and MT. Using fixed or random weighted effect, we evaluated the following outcomes: 3-month mortality, modified Rankin Score (mRs) 0-2, recanalisation success (thrombolysis in cerebral infarction (TICI) ≥2b) and symptomatic intracerebral haemorrhagic (sICH) transformation.

Results: We identified seven cohorts (including three dedicated randomised controlled trials), totalling 1929 patients (932 with GA). Over the entire sample, mortality, mRs 0-2, TICI≥2b and sICH rates were, respectively 17.5% (99% CI 9.7% to 29.6%; Q-value: 60.1; I2: 93%, 1717 patients), 42.1% (99% CI 33.3% to 51.7%; Q-value: 41.3; I2: 87.9%), 82.9% (99% CI 74.0% to 89.1%; Q-value: 20.7; I2: 80.6%, 1006 patients) and 5.5% (99% CI 2.8% to 10.8%; Q-value: 18.6; I2: 78.5%). MT performed in non-GA patients was associated with better 3-month functional outcome (pooled OR, 1.35; 99% CI 1.04 to 1.76; Q-value: 24.0; I2: 9.2%, 1845 patients) and lower 3-month mortality rate (pooled OR, 0.70; 99% CI 0.49 to 0.98; Q-value: 1.4; I2: 0%, 1717 patients; fixed weighted effect model) compared with GA. MT performed under conscious sedation non-GA had significantly shorter onset-to-recanalisation and onset-to-groin delay compared with GA, and recanalisation success and sICH were similar.

Conclusion: Non-GA during MT for anterior acute ischaemic stroke with current-generation stent retriever/aspiration devices is associated with better 3-month functional outcome and lower mortality rates. These unadjusted estimates are subject to biases and should be interpreted with caution.

Keywords: anesthesiology; meta analysis; outcome; stroke care; thrombectomy.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Anesthesia, General / methods*
  • Brain Ischemia / surgery*
  • Cerebral Hemorrhage / epidemiology*
  • Conscious Sedation / methods*
  • Humans
  • Mortality
  • Stroke / surgery*
  • Thrombectomy / methods*
  • Treatment Outcome