Research on the Crack Risk of Early-Age Concrete under the Temperature Stress Test Machine

Materials (Basel). 2018 Sep 25;11(10):1822. doi: 10.3390/ma11101822.

Abstract

A new temperature stress test machine (TSTM) was developed to improve temperature control accuracy and efficiency. As there is no uniform standard for the threshold value of TSTM, quite different threshold values are used in the test, which results in the influences of the threshold value on the evaluation of thermal stresses and crack risk of concrete not being determined. To illustrate the importance of an appropriate threshold value, different threshold values were used to evaluate the influences on the thermal stresses and cracking resistance of concrete specimens under a complete restraint test with semi-adiabatic temperature development. The results show that the maximum compressive stress of a concrete specimen with a threshold value 3 με was slightly larger than that of 1.5 με when the growth rate of tensile stress of the concrete specimen with the threshold value 3 με was slightly greater than that of concrete specimen with the threshold value 1.5 με. Based on the combination of crack risk coefficient and restraint degree, a new system for evaluating the crack resistance of concrete was proposed, in which different threshold values were used to estimate their influences on the crack risk of concrete. Thus, an appropriate range of threshold values could be determined.

Keywords: complete restraint test; crack risk; temperature stress test machine; threshold value.