Risk factors and outcomes for airway failure versus non-airway failure in the intensive care unit: a multicenter observational study of 1514 extubation procedures

Crit Care. 2018 Sep 23;22(1):236. doi: 10.1186/s13054-018-2150-6.

Abstract

Background: Patients liberated from invasive mechanical ventilation are at risk of extubation failure, including inability to breathe without a tracheal tube (airway failure) or without mechanical ventilation (non-airway failure). We sought to identify respective risk factors for airway failure and non-airway failure following extubation.

Methods: The primary endpoint of this prospective, observational, multicenter study in 26 intensive care units was extubation failure, defined as need for reintubation within 48 h following extubation. A multinomial logistic regression model was used to identify risk factors for airway failure and non-airway failure.

Results: Between 1 December 2013 and 1 May 2015, 1514 patients undergoing extubation were enrolled. The extubation-failure rate was 10.4% (157/1514), including 70/157 (45%) airway failures, 78/157 (50%) non-airway failures, and 9/157 (5%) mixed airway and non-airway failures. By multivariable analysis, risk factors for extubation failure were either common to airway failure and non-airway failure: intubation for coma (OR 4.979 (2.797-8.864), P < 0.0001 and OR 2.067 (1.217-3.510), P = 0.003, respectively, intubation for acute respiratory failure (OR 3.395 (1.877-6.138), P < 0.0001 and OR 2.067 (1.217-3.510), P = 0.007, respectively, absence of strong cough (OR 1.876 (1.047-3.362), P = 0.03 and OR 3.240 (1.786-5.879), P = 0.0001, respectively, or specific to each specific mechanism: female gender (OR 2.024 (1.187-3.450), P = 0.01), length of ventilation > 8 days (OR 1.956 (1.087-3.518), P = 0.025), copious secretions (OR 4.066 (2.268-7.292), P < 0.0001) were specific to airway failure, whereas non-obese status (OR 2.153 (1.052-4.408), P = 0.036) and sequential organ failure assessment (SOFA) score ≥ 8 (OR 1.848 (1.100-3.105), P = 0.02) were specific to non-airway failure. Both airway failure and non-airway failure were associated with ICU mortality (20% and 22%, respectively, as compared to 6% in patients with extubation success, P < 0.0001).

Conclusions: Specific risk factors have been identified, allowing us to distinguish between risk of airway failure and non-airway failure. The two conditions will be managed differently, both for prevention and curative strategies.

Trial registration: ClinicalTrials.gov, NCT 02450669 . Registered on 21 May 2015.

Trial registration: ClinicalTrials.gov NCT02450669.

Keywords: Airway; Extubation; Non-airway, weaning.

Publication types

  • Multicenter Study
  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Airway Extubation / methods
  • Airway Extubation / standards*
  • Airway Management / methods
  • Airway Management / standards
  • Female
  • Humans
  • Intensive Care Units / organization & administration
  • Intensive Care Units / statistics & numerical data
  • Length of Stay / statistics & numerical data
  • Logistic Models
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Outcome Assessment, Health Care / methods
  • Prospective Studies
  • Respiration, Artificial / methods
  • Respiration, Artificial / standards
  • Risk Factors
  • Time Factors

Associated data

  • ClinicalTrials.gov/NCT02450669