EXPLORING CORTICAL BONE DENSITY THROUGH THE ULTRASOUND INTEGRATED REFLECTION COEFFICIENT

Acta Ortop Bras. 2018;26(4):255-259. doi: 10.1590/1413-785220182604177202.

Abstract

Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick).

Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT).

Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments.

Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.

Objetivo: Este estudo avalia a relação entre a reflexão ultrassônica e a densidade óssea de 14 amostras cilíndricas de osso cortical bovino (3,0 cm de espessura).

Métodos: Foi realizada a aquisição de 20 sinais de reflexão ultrassônica por amostra (passo de 2,0 mm), ao longo da superfície óssea. O Coeficiente de Reflexão Integrado (IRC) de cada sinal foi comparado por Tomografia Computadorizada Quantitativa (QCT).

Resultados: Sete curvas de IRC e QCT apresentaram valor de Correlação R de Pearson acima de 0,5. Para curvas de correlação fraca, QCT e IRC apresentaram tendências semelhantes em vários segmentos.

Conclusão: O IRC foi sensível à variação da densidade óssea. Nível de evidência: Estudo Experimental, Investigação de Exame Diagnóstico.

Keywords: Bone and Bones; Bone density; Cortical bone; Tomography; Ultrasonics.