Use of lung treatment plans to evaluate DIR algorithms

Australas Phys Eng Sci Med. 2018 Dec;41(4):837-845. doi: 10.1007/s13246-018-0677-0. Epub 2018 Aug 24.

Abstract

The purpose of the study is to evaluate the accuracy of two deformable image registration algorithms by examining their influence on the dose summation results obtained using 4DCT (four dimensional computed tomography) dose distributions based on '4D' planned and '4D optimal' IMRT (intensity modulated radiation therapy) plans. For ten lung cancer patients, 4D step and shoot IMRT plans were produced. The breathing cycle was divided into ten parts and for each part a set of CT images was acquired. For each patient the treatment plan was copied to the CTs of each phase and subsequently recalculated. Each phase CT was then registered to the average intensity projection (AIP) CT using a deformable image registration (DIR) algorithm and the composite dose distribution was then calculated by summing up the deformed dose distributions from all the phases ('4D' treatment plan). The '4D optimal' treatment plan was created by producing an optimal plan on the CTs of each phase of the respiratory cycle and summing up the deformed dose distributions from all the phases. The results indicate that it is possible to map the dose distributions of different breathing phases in lung using DIR, and that different DIR methods and target characteristics (motion amplitude, size, location) affect the differences between original plan, '4D' and '4D optimal' dose distributions. Although the '4D optimal' plans were designed to achieve 95% target coverage, both of the used DIR methods failed to translate that coverage in some instances. The same variation between these methods was also observed in the '4D' plan comparison. This study shows that it is feasible to perform an acceptably accurate calculation of the composite deformed dose. However, it is important to account for tumor motion and body deformation especially when the tumor volume is small and/or located in the lower lobe of the lung.

Keywords: 4DCT; AIP; Deformable image registration; IMRT; Lung; Respiratory phases.

MeSH terms

  • Algorithms
  • Four-Dimensional Computed Tomography / methods*
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Lung / diagnostic imaging
  • Lung Neoplasms / diagnostic imaging*
  • Lung Neoplasms / radiotherapy
  • Radiotherapy Planning, Computer-Assisted / methods*
  • Radiotherapy, Intensity-Modulated
  • Respiration