One-Piece Implants with Smooth Concave Neck to Enhance Soft Tissue Development and Preserve Marginal Bone Levels: A Retrospective Study with 1- to 6-Year Follow-Up

Biomed Res Int. 2018 Jul 24:2018:2908484. doi: 10.1155/2018/2908484. eCollection 2018.

Abstract

Novel one-piece implants with concave smooth neck have been introduced to promote the formation of a thick mucosal layer and preserve marginal bone. A retrospective study on 70 patients with 1- to 6-year follow-up was carried out. Cumulative survival rates were assessed. Variations of marginal bone level were measured on periapical radiographs as distance of the implant-abutment junction from the bone crest. Influence of different variables on treatment outcome was evaluated. Cumulative success rate after 6 years was 99.4 % at implant level and 98.6 % at patient level. Marginal bone level changed in a significant way over time. After 4 months, an increase of radiographic bone level of 0.173 ± 1.088 mm at implant level and 0.18 ± 1.019 mm at patient level was recorded. Mean marginal bone loss after 5 years was 0.573 ± 0.966 mm at implant level and 0.783 ± 1.213 mm at patient level. Age, sex, smoking habits, implant sites, implant lengths and diameters, prosthetic retentions, and timing of loading did not influence marginal bone remodeling in a statistically significant way. At 4-year follow-up partial restorations lost a mean of 0.96 mm of more marginal bone compared with single restorations. This difference was statistically significant.

MeSH terms

  • Adult
  • Aged
  • Alveolar Bone Loss
  • Dental Implantation, Endosseous*
  • Dental Implants
  • Dental Implants, Single-Tooth
  • Dental Prosthesis Design*
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Retrospective Studies
  • Treatment Outcome
  • Young Adult

Substances

  • Dental Implants