Protecting against electrode insertion trauma using dexamethasone

Cochlear Implants Int. 2019 Jan;20(1):1-11. doi: 10.1080/14670100.2018.1509531. Epub 2018 Aug 20.

Abstract

Objective: To compare the benefits of a dexamethasone-eluting array for hearing preservation and cochlear histopathology in low trauma (soft-surgery) and high trauma models of cochlear implant surgery.

Methods: Adult guinea pigs were implanted with an intra-cochlear array using two different surgical procedures: either a soft-surgery approach or following generation of electrode insertion trauma (high trauma). Two methods of dexamethasone delivery were evaluated: elution from an electrode array alone, and elution from a cochlear implant electrode array in combination with a pre-operative systemic injection. All electrode arrays were implanted for a period of 4 weeks. Outcome measures at 4 weeks post-implantation included auditory brainstem response (ABR) thresholds, histological analysis of spiral ganglion neuron density, fibrotic tissue, new bone growth, and cochlear damage.

Results: Animals exposed to high surgical trauma showed greater hearing loss than those in the low trauma model, irrespective of the presence of dexamethasone. Whilst the area of intra-cochlear fibrotic tissue growth post-implantation was also independent of dexamethasone administration, new bone growth was significantly reduced in its presence. Our high trauma model effectively obliterated the organ of Corti and significantly reduced spiral ganglion neuron densities in the lower basal turn. This trauma-induced reduction in spiral ganglion neuron survival decreased with the inclusion of a dexamethasone-eluting array. A pre-operative systemic injection of dexamethasone did not significantly improve any outcome measures beyond those provided with a dexamethasone-eluting array alone.

Conclusion: Dexamethasone-eluting intra-cochlear arrays may inhibit osteoneogenesis, and reduce spiral ganglion neuron loss following traumatic cochlear implantation.

Keywords: Bone growth; Cochlear implant; Corticosteroid; Dexamethasone; Electrode insertion trauma; Eluting electrode array; Fibrous tissue growth.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Cochlea / drug effects
  • Cochlea / surgery
  • Cochlear Implantation / adverse effects*
  • Cochlear Implantation / methods
  • Cochlear Implants / adverse effects*
  • Dexamethasone / administration & dosage*
  • Glucocorticoids / administration & dosage*
  • Guinea Pigs
  • Hearing / drug effects
  • Hearing Loss / etiology
  • Hearing Loss / prevention & control*
  • Postoperative Complications / prevention & control*
  • Spiral Ganglion / drug effects
  • Spiral Ganglion / surgery

Substances

  • Glucocorticoids
  • Dexamethasone