Substituting gelatine with Pluronic F-127 matrix in 3D polymer gel dosimeters can improve nuclear magnetic resonance, thermal and optical properties

Phys Med Biol. 2018 Sep 6;63(17):175010. doi: 10.1088/1361-6560/aad9d5.

Abstract

This work discusses the substitution of a gelatine physical gel matrix with a matrix made of poly(ethylene oxide)-block-poly(propylene oxide)-block-poly(ethylene oxide) (Pluronic F-127) in five 3D radiotherapy polymer gel dosimeters: MAGAT, PAGAT, NIPAM, VIPARnd (VIP) and VIPARCT (VIC). The current research outcomes showed that not each polymer gel dosimeter could be manufactured with Pluronic F-127. Two of the polymer gel dosimeters (PAGAT and VIP) containing the Pluronic F-127 matrix allowed for some proper dose response for radiotherapy dosimetry (a response to a dose range of e.g. 0‒50 Gy). The new best performing Pluronic-based polymer gel dosimeters were characterised by improved nuclear magnetic resonance properties, when being compared to gels with gelatine matrix at the same monomer content. These are: (i) a ~33% higher dose sensitivity; (ii) a comparable or slightly higher linear and dynamic dose range and (iii) a lower (new VIP composition, VIP3) or equivocal (new PAGAT composition, PAGAT2-Pluronic) dose threshold. However, there might be optimised gelatine based polymer dosimeters demonstrating even better sensitivity. UV-vis spectrophotometry measurements revealed that Pluronic matrices ensure six-times lower (VIP3-Pluronic) and eight-times lower (PAGAT2-Pluronic) absorbance (at 400 nm) of non-irradiated gels compared to gelatine matrices, which makes the new polymer gel dosimeters optically improved in comparison to their corresponding gelatine-based compositions. The differences in absorption reduce for higher wavelengths. Differential scanning calorimetry measurements revealed the following temperature stability ranges for the gels: (i) VIP with gelatine matrix: 0 °C‒26 °C, (ii) VIP3 with Pluronic matrix: 13.8 °C-55.2 °C, (iii) PAGAT2 with gelatine matrix: 0 °C-80 °C and (iv) PAGAT2 with Pluronic matrix: 21.4 °C-55.2 °C. In conclusion, Pluronic F-127 is an attractive co-polymer to serve as a substitute for the gelatine matrix in some 3D polymer gel dosimeters.

MeSH terms

  • Gelatin / chemistry*
  • Gels / chemistry*
  • Humans
  • Magnetic Resonance Spectroscopy / methods*
  • Phantoms, Imaging*
  • Poloxamer / chemistry*
  • Polymers / chemistry
  • Radiation Dosimeters*
  • Radiometry / instrumentation*
  • Temperature

Substances

  • Gels
  • Polymers
  • Poloxamer
  • Gelatin