Physician-Modified Fenestrated Endografts for Managing the Ruptured or Symptomatic Aortic Aneurysm: Technique Overview and Clinical Outcomes

Vasc Endovascular Surg. 2018 Nov;52(8):607-612. doi: 10.1177/1538574418789023. Epub 2018 Jul 22.

Abstract

Purpose:: Fenestrated endovascular aneurysm repair (FEVAR) grafts have a 10- to 12-week manufacturing time and are generally not available for emergency cases of symptomatic or ruptured aortic aneurysm. In the absence of other alternatives, conventional off-the-shelf stent grafts can be modified by trained operators to treat these complex cases. The aim of this study is to present a single-center experience of physician-modified FEVAR.

Methods:: A retrospective review was performed of all physician-modified FEVAR identified from the hospital endovascular database at a single tertiary referral center between September 1996 and September 2017.

Results:: Eight cases of urgent or emergency endovascular aneurysm repair (EVAR) with physician-modified grafts were identified. Mean follow-up was 44 weeks (range: 5-106 weeks). Outcomes for all implanted grafts (7/8 cases) included 100% technical success, 14% rate of endoleak, no procedure-related complications, no adverse visceral events, 0% 30-day mortality and 100% 1-year target vessel patency, and freedom from aneurysm-related death. There was a 14% (1/7 cases) per patient reintervention rate.

Conclusion:: Modifying EVAR grafts is a highly technical process requiring meticulous planning and extensive elective experience with FEVAR. The current series demonstrates that physician modification of endografts for urgent or emergency abdominal aortic aneurysm repair is feasible and a safe alternative to open surgical aneurysm repair.

Keywords: physician-modified fenestrated endovascular aneurysm repair.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / physiopathology
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortic Rupture / diagnostic imaging
  • Aortic Rupture / physiopathology
  • Aortic Rupture / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Endoleak / etiology
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Prosthesis Design
  • Retrospective Studies
  • Risk Factors
  • Stents*
  • Time Factors
  • Treatment Outcome
  • Vascular Patency