Polymer-free drug-coated coronary stents in diabetic patients at high bleeding risk: a pre-specified sub-study of the LEADERS FREE trial

Clin Res Cardiol. 2019 Jan;108(1):31-38. doi: 10.1007/s00392-018-1308-1. Epub 2018 Jun 27.

Abstract

Objective: Diabetics are at increased risk after stent implantation and potentially sensitive to the type of stent and dual anti-platelet therapy (DAPT). The randomized, double-blind LEADERS FREE trial compared 2432 patients at high bleeding risk (HBR) receiving either a polymer-free BA9-coated stent (DCS) or a bare metal stent (BMS) with 1 month of DAPT, and showed superior safety and efficacy of the DCS at 2 years. We report outcomes at 2 years of the pre-specified diabetic subgroup.

Methods and results: The diabetic sub-group comprised 805 (33.1%) patients; 262 (10.8%) were insulin-dependent (IDDM). Compared to non-diabetics, diabetics were younger and had more risk factors and multi-vessel disease. They suffered higher rates of death (15.6 vs. 12.2%, p = 0.01), cardiac death (8.3 vs. 5.9%, p = 0.02), myocardial infarction (MI) (11.1 vs. 7.8%, p = 0.009) and definite/probable stent thrombosis (3.1 vs. 1.7%, p = 0.01), but rates of clinically-indicated TLR (9.1 vs. 9.5%, p = 0.93) and BARC 3-5 bleeding (10.2 vs. 8.4%, p = 0.20) were comparable. Compared to diabetic patients treated with a BMS, diabetic DCS recipients required less clinically driven TLR (6.3 vs. 12.2%, p = 0.006). The primary safety endpoint (cardiac death, MI, definite/probable stent thrombosis) occurred numerically less frequently in the DCS group (14.9 vs. 19.7%, p = 0.10), and was significantly lower in IDDM patients (13.8 vs. 25.4%, p = 0.03). BARC 3-5 was similar for patients treated with DCS (9.9%) and BMS (10.5%, p = 0.84).

Conclusions: In diabetic HBR patients, DCS significantly reduced re-intervention rates over BMS, and showed a strong trend towards a safety benefit at 2 years.

Clinical trial registration: ClinicalTrials.gov number: NCT01623180.

Keywords: Bleeding; Diabetes mellitus; Drug-coated stents.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Coronary Artery Disease / surgery*
  • Coronary Thrombosis / prevention & control*
  • Diabetes Mellitus*
  • Double-Blind Method
  • Drug-Eluting Stents*
  • Europe / epidemiology
  • Female
  • Follow-Up Studies
  • Humans
  • Incidence
  • Male
  • Percutaneous Coronary Intervention / methods*
  • Polymers
  • Postoperative Hemorrhage / epidemiology*
  • Prosthesis Design
  • Risk Factors
  • Time Factors
  • Treatment Outcome

Substances

  • Polymers

Associated data