Over-voluming predicted by pre-operative planning in 24% of total knee arthroplasty

Knee Surg Sports Traumatol Arthrosc. 2019 May;27(5):1544-1551. doi: 10.1007/s00167-018-4998-z. Epub 2018 Jun 2.

Abstract

Purpose: Numerous studies demonstrated that prosthetic overhang and over-sizing cause pain and stiffness following total knee arthroplasty (TKA), but none considered volume changes within the joint capsule. This study was designed to investigate differences in volumes of resected bone compared to implanted components in TKA, and to determine the incidence and factors related to 'over-voluming'.

Methods: Three-dimensional reconstructions were created from 100 magnetic resonance imaging scans taken to design patient-specific instruments for TKA. The preoperative simulations were used to calculate the volume ratio (VR) by dividing volume of planned components by that of planned bone resections. Uni- and multi-variable linear regressions were performed to determine associations between 'over-voluming' (VR > 1.0) and gender, implant size and version (standard versus narrow), osteophytes, resection levels, external rotation of the femoral component, hip-knee-ankle (HKA) angle, mechanical lateral distal femoral angle (mLDFA), and mechanical medial proximal tibial angle (mMPTA).

Results: The overall implant/bone volume ratio was 0.91 ± 0.11 (range 0.63-1.16) with 'over-voluming' observed in 24 knees. Multi-variable regression confirmed over-voluming to be associated with lower mLDFA (OR 0.66; CI 0.45-0.93; p = 0.026) and extensive osteophytes (OR 0.14; CI 0.03-0.61; p = 0.014), but not HKA angle (OR 0.98; CI 0.76-1.26; p = n.s.).

Conclusions: Over-voluming was observed in 24% of knees, in which the implant volume exceeded the resected volume by up to 16%. Over-voluming was associated with intra-articular femoral valgus (low mLDFA), but not directly associated with tibial deformity (mMPTA) or HKA angle. Over-voluming could be associated with prosthetic overhang or excessive tensions within the joint capsule, and, therefore, contribute to unexplained pain and stiffness following TKA.

Level of evidence: IV, Retrospective cohort study.

Keywords: Over-sizing; Overhang; Pain; Stiffness; Total knee arthroplasty; Volume.

MeSH terms

  • Aged
  • Ankle Joint / surgery
  • Arthroplasty, Replacement, Knee / methods*
  • Equipment Design
  • Female
  • Femur / diagnostic imaging
  • Femur / surgery
  • Humans
  • Image Processing, Computer-Assisted
  • Imaging, Three-Dimensional
  • Knee Joint / diagnostic imaging
  • Knee Joint / surgery*
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Multivariate Analysis
  • Osteoarthritis, Knee / diagnostic imaging
  • Osteoarthritis, Knee / surgery*
  • Osteophyte / surgery
  • Patient Satisfaction
  • Preoperative Care / methods*
  • Reproducibility of Results
  • Retrospective Studies
  • Rotation
  • Surgery, Computer-Assisted / methods
  • Tibia / surgery*
  • Tomography, X-Ray Computed