Platinum corrosion products from electrode contacts of human cochlear implants induce cell death in cell culture models

PLoS One. 2018 May 15;13(5):e0196649. doi: 10.1371/journal.pone.0196649. eCollection 2018.

Abstract

Despite the technological progress made with cochlear implants (CI), impedances and their diagnosis remain a focus of interest. Increases in impedance have been related to technical defects of the electrode as well as inflammatory and/or fibrosis along the electrode. Recent studies have demonstrated highly increased impedances as the result of corroded platinum (Pt) electrode contacts. This in vitro study examined the effects of Pt ions and compounds generated by corrosion of the electrode contacts of a human CI on cell metabolism. Since traces of solid Pt in surrounding cochlear tissues have been reported, the impact of commercially available Pt nanoparticles (Pt-NP, size 3 nm) on the cell culture model was also determined. For this purpose, the electrode contacts were electrically stimulated in a 0.5% aqueous NaCl solution for four weeks and the mass fraction of the platinum dissolute (Pt-Diss) was determined by mass spectrometry (ICP-MS). Metabolic activity of the murine fibroblasts (NIH 3T3) and the human neuroblastoma (SH-SY5Y) cells was determined using the WST-1 assay following exposure to Pt-Diss and Pt-NP. It was found that 5-50 μg/ml of the Pt-NP did not affect the viability of both cell types. In contrast, 100 μg/ml of the nanoparticles caused significant loss in metabolic activity. Furthermore, transmission electron microscopy (TEM) revealed mitochondrial swelling in both cell types indicating cytotoxicity. Additionally, TEM demonstrated internalized Pt-NP in NIH 3T3 cells in a concentration dependent manner, whereas endocytosis in SH-SY5Y cells was virtually absent. In comparison with the Pt-NP, the corrosion products (Pt-Diss) with concentrations between 1.64 μg/ml and 8.2 μg/ml induced cell death in both cell lines in a concentration dependent manner. TEM imaging revealed both mitochondrial disintegration and swelling of the endoplasmic reticulum, suggesting that Pt ions trigger cytotoxicity in both NIH 3T3 and SH-SY5Y cell lines by interacting with the respiratory chain.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Cell Culture Techniques
  • Cell Death / drug effects*
  • Cell Line, Tumor
  • Cell Survival / drug effects
  • Cochlear Implantation / methods
  • Cochlear Implants
  • Corrosion
  • Electrodes
  • Endocytosis / drug effects
  • Endoplasmic Reticulum / drug effects
  • Humans
  • Metal Nanoparticles / administration & dosage*
  • Metal Nanoparticles / chemistry*
  • Mice
  • Mitochondria / drug effects
  • NIH 3T3 Cells
  • Platinum / administration & dosage*
  • Platinum / chemistry*

Substances

  • Platinum

Grants and funding

This work was supported by a grant by the Deutsche Forschungsgemeinschaft, 240032230, recipients: Martin Durisin and Thomas Lenarz. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.