Three-years outcomes of diabetic patients treated with coronary bioresorbable scaffolds

BMC Cardiovasc Disord. 2018 May 10;18(1):92. doi: 10.1186/s12872-018-0811-7.

Abstract

Background: Diabetes is among the strongest predictors of outcome after coronary artery stenting and the incidence of negative outcomes is still high in this specific group. Data of long-term outcomes comparing diabetic patients with non-diabetic patients treated with bioresorbable scaffolds are still incomplete. This work evaluates the long-term outcomes after implantation of a coronary bioresorbable scaffold (BRS) in diabetic patients compared to non-diabetics.

Methods: Patients who received at least one Absorb BRS in the time of May 2012 to December 2014 were enrolled into this single-center registry. Quantitative coronary angiography (QCA) was performed.

Results: Six hundred fifty seven patients including 138 patients (21%, mean age 65 ± 11, 78% male) with diabetes were enrolled. Patients in the diabetic group were significantly older, were more likely to suffer from hypertension and hyperlipidemia and had more often a prior stroke or TIA as well as a reduced renal function (all P < 0.05). The initial stenosis was less severe in the diabetic group (74.8% vs. 79.6%, P = 0.036), but the residual stenosis after BRS implantation exceeded that of the control group (16.7% vs. 13.8%, P = 0.006). History of diabetes had no impact on the incidence of events within one year after BRS implantation. Beyond 1 year, diabetic patients had a higher incidence of cardiovascular death (6.9 vs. 1.4%, HR:5.37 [1.33-21.71], P = 0.001), scaffold restenosis (17.6 vs. 7.8%, HR:3.56 [1.40-9.05], P < 0.0001) and target lesion revascularization (P = 0.016). These results were confirmed in the propensity score analysis. In both diabetics and non-diabetics, there was a strong association (HR:18.6 [4.7-73.3]) between the risk of restenosis and the technique used at implantation; in contrast, the impact of vessel size was more manifest in non-diabetics than in diabetic patients, and an increased risk of restenosis was demonstrated for both large and small vessels.

Conclusion: As for metal stents, beyond one year after implantation, diabetes was associated with an increased incidence of scaffold restenosis and related outcomes. This negative impact of diabetes was reset when an optimal implantation technique was used.

Keywords: Bioresorbable scaffolds; Coronary artery disease; Diabetes.

Publication types

  • Comparative Study
  • Observational Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / mortality
  • Coronary Artery Disease / surgery*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / epidemiology
  • Diabetes Mellitus / diagnosis
  • Diabetes Mellitus / epidemiology*
  • Diabetes Mellitus / mortality
  • Female
  • Germany / epidemiology
  • Humans
  • Incidence
  • Male
  • Middle Aged
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Percutaneous Coronary Intervention / mortality
  • Prosthesis Design
  • Registries
  • Retrospective Studies
  • Risk Factors
  • Time Factors
  • Treatment Outcome