Automated EEG background analysis to identify neonates with hypoxic-ischemic encephalopathy treated with hypothermia at risk for adverse outcome: A pilot study

Pediatr Neonatol. 2019 Feb;60(1):50-58. doi: 10.1016/j.pedneo.2018.03.010. Epub 2018 Apr 4.

Abstract

Background: To improve the objective assessment of continuous video-EEG (cEEG) monitoring of neonatal brain function, the aim was to relate automated derived amplitude and duration parameters of the suppressed periods in the EEG background (dynamic Interburst Interval= dIBIs) after neonatal hypoxic-ischemic encephalopathy (HIE) to favourable or adverse neurodevelopmental outcome.

Methods: Nineteen neonates (gestational age 36-41 weeks) with HIE underwent therapeutic hypothermia and had cEEG-monitoring. EEGs were retrospectively analyzed with a previously developed algorithm to detect the dynamic Interburst Intervals. Median duration and amplitude of the dIBIs were calculated at 1 h-intervals. Sensitivity and specificity of automated EEG background grading for favorable and adverse outcomes were assessed at 6 h-intervals.

Results: Dynamic IBI values reached the best prognostic value between 18 and 24 h (AUC of 0.93). EEGs with dIBI amplitude ≥15 μV and duration <10 s had a specificity of 100% at 6-12 h for favorable outcome but decreased subsequently to 67% at 25-42 h. Suppressed EEGs with dIBI amplitude <15 μV and duration >10 s were specific for adverse outcome (89-100%) at 18-24 h (n = 10). Extremely low voltage and invariant EEG patterns were indicative of adverse outcome at all time points.

Conclusions: Automated analysis of the suppressed periods in EEG of neonates with HIE undergoing TH provides objective and early prognostic information. This objective tool can be used in a multimodal strategy for outcome assessment. Implementation of this method can facilitate clinical practice, improve risk stratification and aid therapeutic decision-making. A multicenter trial with a quantifiable outcome measure is warranted to confirm the predictive value of this method in a more heterogeneous dataset.

Keywords: automated EEG analysis; dynamic Interburst Interval; hypoxic-ischemic encephalopathy; outcome prediction.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Electroencephalography / methods*
  • Female
  • Humans
  • Hypothermia, Induced*
  • Hypoxia-Ischemia, Brain / diagnosis
  • Hypoxia-Ischemia, Brain / physiopathology*
  • Hypoxia-Ischemia, Brain / therapy*
  • Infant, Newborn
  • Male
  • Pilot Projects
  • Prognosis
  • Retrospective Studies
  • Sensitivity and Specificity