In-Line Filtration Reduces Postoperative Venous Peripheral Phlebitis Associated With Cannulation: A Randomized Clinical Trial

Anesth Analg. 2018 Dec;127(6):1367-1374. doi: 10.1213/ANE.0000000000003393.

Abstract

Background: Peripheral venous cannulation is an everyday practice of care for patients undergoing anesthesia and surgery. Particles infused with intravenous fluids (eg, plastic/glass/drugs particulate) contribute to the pathogenesis of peripheral phlebitis. The aim of this study is to demonstrate the efficacy of in-line filtration in reducing the incidence of postoperative phlebitis associated with peripheral short-term vascular access.

Methods: In this controlled trial, 268 surgical patients were randomly assigned to in-line filtration and standard care (NCT03193827). The incidence of phlebitis (defined as visual infusion phlebitis [VIP] score, ≥2) within 48 hours was compared between the 2 groups, as well as the onset and severity of phlebitis and the reasons for removal of the cannula. The lifespan of venous cannulae was compared for the in-line filter and no-filter groups through a Kaplan-Meier curve.

Results: The incidence of phlebitis within 48 hours postoperatively was 2.2% and 26.9% (difference, 25% [95% confidence interval {CI}, 12%-36%]; odds ratio, 0.05 [0.01-0.15]), respectively, for the in-line filter and no-filter groups (P < .001). From 24 to 96 hours postoperatively, patients in the no-filter group had higher VIP scores than those in in-line filter group (P < .001). Venous cannulae in the in-line filter group exhibited prolonged lifespan compared to those in the no-filter group (P = .01). In particular, 64 (47.8%) of cannulae in the in-line filter group and 56 (41.8%) of those in the no-filter group were still in place at 96 hours postoperatively. At the same time point, patients with a VIP score <3 were 100% in the in-line filter group and only 50% for the no-filter group. In-line filtration was a protective factor for postoperative phlebitis (hazard ratio, 0.05 [95% CI, 0.014-0.15]; P < .0001) and cannula removal (hazard ratio, 0.7 [95% CI, 0.52-0.96]; P = .02).

Conclusions: In-line filtration has a protective effect for postoperative phlebitis and prolongs cannula lifespan during peripheral venous cannulation in surgical patients.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Anesthesia
  • Catheterization / adverse effects*
  • Catheterization, Peripheral / adverse effects*
  • Female
  • Filtration*
  • Humans
  • Incidence
  • Infusions, Intravenous
  • Kaplan-Meier Estimate
  • Male
  • Middle Aged
  • Phlebitis / etiology*
  • Phlebitis / prevention & control*
  • Postoperative Complications / prevention & control
  • Postoperative Period
  • Prevalence
  • Proportional Hazards Models
  • Prospective Studies
  • Vascular Access Devices

Associated data

  • ClinicalTrials.gov/NCT03193827